TO REPLACE THE LINEAR ACTUATOR
10. Re-install linear
actuator into rack
assembly. If motor
does not clear the
cross member, use
pry bar to gently
lift and fi t as previ-
ous done in step 3.
Reinstall actuator
base pin from in-
side and remount
its spring clip.
11. Gently fi t clevis clip through top of actua-
tor shaft and cross member bar. Use pry bar
to align holes.
TO REPLACE THE SHAFT SEALS
1. Top platen be in
the upper posi-
tion when replac-
ing the shaft seal.
With the control
in the OFF mode,
press green but-
tom to upper plat-
en, then turn the
main switch OFF.
2. Remove back panel to access seal cap
mounting bracket, hold bracket while tak-
ing screws off the seal cap.
PART #4527466 (12 Aug 2011)
INSTALLATION/OPERATION & SERVICE MANUAL - 1&2 PLATEN
(continued)
12. Follow procedures 1 & 2 reversing the
steps. Clip must installed in place to secure
plug. Replace plastic-ties by new ones.
3. Using a 1/4" sock-
et, remove screws
from seal cap to
expose the old
shaft seal under-
neath.