INSTALLATION/OPERATION & SERVICE MANUAL - 1&2 PLATEN

PROBE CALIBRATION

Monthly Calibration of Grill Temperature Zones
Tools: Digital Pyrometer with Surface Probe
Warning: PERSONAL INJURY FROM BURNS MAY RESULT
WHEN COMING IN CONTACT WITH HOT COOKING
SURFACES.
NOTE: Probe Calibration of grills is done with release
material sheets "OFF".
PLEASE FOLLOW THESE INSTRUCTIONS EXACTLY
AS THEY APPEAR BELOW:
1. The upper platens and lower grill plate should be at
operating temperatures to perform this calibration
procedure. Press the
"CLAM" operation and allow the grill to reach the set
temperature and stabilize, (approximately 30 minutes).
2. PRESS and HOLD the
3 seconds, or until the controller will display:
"PROBE CAL".
3. PRESS the
button to display the fi rst temperature
zone to be calibrated. The fi rst zone to be calibrated is
"FRONT TEMP CAL". The zones are displayed in order of
FRONT TEMP CAL, MIDDLE TEMP CAL, BACK TEMP CAL,
TOP TEMP CAL.
MWE3W:MWE2W: The electric grill's thermocouple
probes are located front to rear, as shown in the
diagram to the right. Each upper platen has one
thermocouple in the center.
MWG3W:MWG2W: The gas grill's thermocouple
probes are located in the center of each lane, as shown
in the diagram to the right. Each upper platen has one
thermocouple in the center.
Page 44
or
button to select a
button for approximately
GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION
4. Select a heat zone display using the
5. Allow at least 5 seconds for the pyrometer to respond
and stabilize. Note the temperature on the pyrometer.
6. If the temperature on the grill control display does not
match the temperature on the pyrometer, adjust the
temperature on the grill control accordingly. The
button will increase the displayed temperature in one,
(1) degree increments. The
displayed temperature in one, (1), degree Increments.
NOTE: During step 6, the control should be sounding
a high-pitched tone. The temperature can only be
adjusted if this tone is sounding. If the control is silent,
the temperature will not change.
7. PRESS the
button to lock the calibrated temperature
into the controller.
8. Press the
or
button to select the next heat zone.
9. Move the pyrometer's surface probe to the newly
selected heat zone and repeat steps 5, 6, and 7.
10. Repeat the procedure for each of the heat zones.
11. Continue to cycle through each heat zone repeating
the sequence until all temperatures are within 1°.
12. Exit the program mode by pressing the
The controller will return to its previous state in the
Normal Operating Mode.
or
buttons.
button will decrease the
button 2x.