Danfoss VLT AQUA Drive FC 202 Design Manual page 46

Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Selection
Normal Load
Typical Shaft output at 550 V [kW]
Typical Shaft output at 575 V [hp]
Typical Shaft output at 690 V [kW]
3
3
Enclosure IP00
Enclosure IP21
Enclosure IP54
Output current
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V)
[A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690
V) [kVA]
Continuous kVA (at 550 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Max. Input current
Continuous (at 550 V) [A]
Continuous (at 575 V) [A]
Continuous (at 690 V) [A]
Max cable size
2
Motor (mm
/AWG
2
Mains (mm
/AWG
Loadsharing (mm
2
Brake (mm
/AWG
Max. external mains fuses [A]
Estimated power loss at 575 V [W]
Estimated power loss at 690 V [W]
Weight, enclosure IP20, IP21, IP54 kg
(lbs.)
4)
Efficiency
Output frequency [Hz]
Heatsink overtemp. trip [°C]
Power card ambient trip [°C]
Table 3.5 Mains Supply 3x525-690 V AC
1) For type of fuse, consult the Operating Instructions.
2) American Wire Gauge.
3) The typical power loss is at normal conditions and expected to be within
These values are based on a typical motor efficiency (eff2/eff3 border line). Lower efficiency motors add to the power loss in the frequency
converter and the opposite is also true. If the switching frequency is raised from nominal, the power losses rise significantly. LCP and typical
control card power consumptions are included. Further options and customer load can add up to 30 W to the losses (though typically only 4 W
extra for a fully loaded control card or options for slot A or slot B, each).
4) Measured using 5 m screened motor cables at rated load and rated frequency.
44
VLT
P630
500
650
630
E2
E1
E1
630
693
630
693
600
627
753
607
607
607
2)
)
4x240
2)
)
(4x500
mcm)
2
/AWG
2)
)
2)
2x185
)
(2x350
mcm)
900
3)
8209
3)
8495
110
MG20Z102 - VLT
®
AQUA Drive FC 202 Design Guide
P710
P800
P900
560
670
750
750
950
1050
710
800
900
F1/F3
F1/F3
F1/F3
F1/F3
F1/F3
F1/F3
763
889
988
839
978
1087
730
850
945
803
935
1040
727
847
941
727
847
941
872
1016
1129
743
866
962
711
828
920
711
828
920
8x150
(8x300 mcm)
8x240
(8x500 mcm)
4x185
(4x350 mcm)
1600
1600
1600
9500
10872
12316
9863
11304
12798
95
105
95
± 15% (tolerance relates to variety in voltage and cable conditions.)
®
is a registered Danfoss trademark
P1M0
P1M2
850
1000
1150
1350
1000
1200
F2/F4
F2/F4
F2/F4
F2/F4
1108
1317
1219
1449
1060
1260
1166
1386
1056
1255
1056
1255
1267
1506
1079
1282
1032
1227
1032
1227
12x150
(12x300 mcm)
8x240
(8x500 mcm)
6x185
(6x350 mcm)
1600
2000
13731
16190
14250
16821
125 (275)
0.98
0–525
105
85
P1M4
1100
1550
1400
F2/F4
F2/F4
1479
1627
1415
1557
1409
1409
1691
1440
1378
1378
2500
18536
19247
95