Mains Contactors - Danfoss VLT AQUA Drive FC 202 Design Manual

Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

How to Install
Frame Size
D6h
D6h
D8h
D8h
D8h
D6h
D8h
D8h
5
5
Table 5.22 D-frame Circuit Breakers
Frame size
F3
F3
F4
F4
Table 5.23 F-frame Circuit Breakers

5.5.2 Mains Contactors

Frame size
D6h
D8h
Table 5.24 D-Frame Contactors
Frame size
F3
F3
F3
F4
F4
Table 5.25 F-Frame Contactors
NOTE
Customer supplied 230 V supply is required for mains contactors.
146
Voltage [V]
Drive Model
380-480
N110 - N132
380-480
N160
380-480
N200
380-480
N250
380-480
N315
525-690
N75K - N160
525-690
N200 - N315
525-690
N400
Power & Voltage
P450 380-500V & P630-P710
525-690V
P500-P630 380-500V & P800
525-690V
P710 380-500V & P900-P1M2
525-690V
P800 380-500V
Power & Voltage
N110-N160 380-480 V
N75-N160 525-690 V
N200-N315 380-480 V
N200-N400 525-690 V
Power & Voltage
P450-P500 380-500 V & P630-P800 525-690 V
P560 380-500 V
P630 380-500 V
P900 525-690 V
P710-P800 380-500 V & P1M2 525-690 V
MG20Z102 - VLT
®
VLT
AQUA Drive FC 202 Design Guide
Circuit Breaker Type
ABB T5L400TW
ABB T5LQ400TW
ABB T6L600TW
ABB T6LQ600TW
ABB T6LQ800TW
ABB T5L400TW
ABB T6L600TW
ABB T6LQ600TW
Type
Merlin Gerin NPJF36120U31AABSCYP
Merlin Gerin NRJF36200U31AABSCYP
Merlin Gerin NRJF36200U31AABSCYP
Merlin Gerin NRJF36250U31AABSCYP
®
is a registered Danfoss trademark
Default breaker settings (Trip level - Amps)
I1 (Overload)
I3/Ith (Instantaneous)
400
4000
400
4000
600
6000
600
6000
800
8000
400
4000
600
6000
600
6000
Default breaker settings
Trip level [A]
Time [s]
1200
2000
2000
2500
Type
CK95BE311N
CK11CE311N
Type
Eaton XTCE650N22A
Eaton XTCE820N22A
Eaton XTCEC14P22B
Eaton XTCE820N22A
Eaton XTCEC14P22B
0.5
0.5
0.5
0.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents