02. Wait a few seconds until the control unit has completed the device recognition procedure: led L2 switches off. If instead it flashes, it means that
there is some error – see Chapter 10.
03. After adding or removing devices, the automation must be tested again (Par. 6.1).

9.3 - MEMORISING ADDITIONAL TRANSMITTERS

The control unit incorporates a radio receiver for ECCO5 transmitters (various models). The transmitters supplied are not memorised, therefore it is first
necessary to memorise the 1
st
transmitter (Par. 5.6); to memorise additional transmitters, it is possible to choose one of the procedures (Mode 1 or
Mode 2) indicated below. The control unit can memorise a total of 250 units: memorisation in Mode 1 occupies one unit of memory for each transmitter,
while the Mode 2 procedure occupies one unit of memory for each transmitter key.
Before running the memorisation procedures, it is advisable to read them and observe the indicated times.
9.3.1 - Mode 1 memorisation procedure (factory memorisation of the supplied transmitters)
This procedure allows for simultaneously memorising all the transmitter keys, by automatically pairing them to the commands shown in Table 4.
A transmitter memorised in Mode 1 can control only a single automation.
TABLE 4
Keys
Paired command
T1
Step-by-step
T2
Partial open
T3
Open only
T4
Close only
T5
Courtesy light: Lit - Off
Memorisation procedure
01. On the control unit (Fig. 27) press and hold button P4 for 3 seconds; when led L4 switches on, release the button.
02. Within 10 seconds from releasing it, press and hold for 3 seconds any button of the transmitter to be memorised.
If the memorisation procedure is successful, led L4 (on the control unit) will flash 3 times.
03. To memorise other transmitters, repeat step 02 within the next 10 seconds otherwise the memorisation phase will terminate automatically.

9.3.2 - Mode 2 memorisation procedure

This procedure allows for memorising one key at a time, by pairing one of the desired commands shown in Table 5.
A transmitter memorised in Mode 2 can control multiple automations (for example: automation 1 controlled by key 1; automation 2 controlled
by key 2; and so forth)
No. of key
Paired command
presses
once
Step-by-step
twice
Pedestrian opening
3 times
Open only
4 times
Close only
5 times
230 V light output: On - Off
6 times
Stop
7 times
Condominium open
8 times
High priority open
9 times
Pedestrian opening 2
10 times
Pedestrian opening 3
11 times
Open + lock automation
12 times
Close + lock automation
13 times
Lock automation
14 times
Release automation
9.3.3 - Memorisation procedure near the control unit with two transmitters (without using the control unit keys)
With this procedure a NEW transmitter is memorised using a second transmitter (OLD) already memorised and operating, without using the keys of
the control unit but drawing close to the latter.
During the procedure the NEW transmitter is memorised in the same way that the OLD transmitter was memorised (Mode 1 or Mode 2).
• Procedure with OLD transmitter memorised in Mode 1:
01. Draw near the control unit with the two transmitters:
02. On the NEW transmitter press and hold any key for at least 8 seconds then release it.
03. On the OLD transmitter press and hold any key to be copied for at least 2 seconds then release it.
04. On the OLD transmitter press and hold any key to be copied for at least 2 seconds then release it.
05. On the OLD transmitter press and hold any key to be copied for at least 2 seconds then release it.
06. On the NEW transmitter press and hold a key to be memorised for at least 5 seconds then release it.
Repeat the procedure for each transmitter to be memorised.
• Procedure with OLD transmitter memorised in Mode 2:
01. Draw near the control unit with the two transmitters:
next.
02. On the NEW transmitter press and hold the key to be memorised for at least 8 seconds then
T1
T3
TABLE 5
No. of flashes of led
L4 on the control
unit
1
2
3
4
14
6
7
8
9
10
11
12
13
14
Wait 1 second between one step and the next.
Wait 1 second between one step and the
LED
T5
T2
T4
Memorisation procedure
01. Before proceeding, it is necessary to cancel the memory of
the transmitter to be memorised – see Par. 9.4.
02. In Table 5, choose the command and the number of press-down
actions to be effected on the desired transmitter key.
03. On the control unit (Fig. 28) press and release button P4 for a
number of times corresponding to the chosen command (Table 5);
led L4 must emit a number of fast flashes corresponding to the
chosen command.
04. Within 10 seconds, press and hold for 2 seconds the key of the
transmitter to be memorised: if the memorisation was successful,
led L4 (on the control unit) will flash 3 times.
05. To memorise other transmitters, with the same command, repeat
step 03 within 10 seconds, otherwise the memorisation phase will
terminate automatically.
27
Aerial
L4
L4
L3
L3
L4
P4
P4
P4
P3
P3
28
Aerial
L4
L4
L3
L3
L4
P4
P4
P4
P3
P3
English – 11
Flash
Flash
Fuse 1.6A T
Fuse 1.6A T
OGI
OGI
ECSbus
ECSbus
Stop
Stop
SbS
SbS
L 3
L
L3
3
L2
L2
L1
L1
SbS
SbS
P3
P
P 3
3
3
P2
P2
P1
P1
Flash
Flash
Fuse 1.6A T
Fuse 1.6A T
OGI
OGI
ECSbus
ECSbus
Stop
Stop
SbS
SbS
L3
L
L 3
3
L2
L2
L1
L1
SbS
SbS
P3
P 3
P
3
3
P2
P2
P1
P1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents