Torch Mode Setting; Up/Down Speed; Current Jump - EWM Microplasma 25 Operating Instructions Manual

Table of Contents

Advertisement

5.7.2

Torch mode setting

Modes 1 to 6 and 11 to 16 are available to the user. Modes 11 to 16 feature the same functionality as 1 to
6, but without the tapping function > see 5.7.1 chapter for the secondary current.
The functionality of the individual modes can be found in the corresponding torch type tables.
The torch modes are set using the torch configuration parameters "
menu > torch mode "
Only the modes listed are suitable for the corresponding torch types.
5.7.3

Up/down speed

Functionality
Press and hold the up push-button:
Increase current up to the maximum value (main current) set in the power source.
Press and hold the down push-button:
Decrease current to the minimum value.
Use the machine configuration menu > see 5.13 chapter to set the up/down speed parameter
determines the speed with which a current change becomes effective.
5.7.4

Current jump

By tapping the corresponding torch trigger the welding current can be determined in an adjustable jump
range. Each tap will cause the welding current to jump up or down by the defined value.
The "current jump" parameter
099-007027-EW501
28.08.2018
" > see 5.13 chapter.
is set in the machine configuration menu > see 5.13 chapter.
Design and function
Welding torch (operating variants)
" in the machine configuration
which
57

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Microplasma 25 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Microplasma 55Microplasma 105

Table of Contents