Parameter
Parameters for
Parameter
TIG welding
38
Description
Break voltage (U cut off)
Used to specify at which arc length the welding
process is completed.
The welding voltage increases as the length of the
arc increases. The arc is extinguished when it
reaches the voltage specified here
Factory setting: 45 volts
Factory setting (FACtory)
This can be used to reset the device to its factory
settings
-
Cancel reset
-
Reset the parameters for the selected weld-
ing process to their factory settings
-
Reset the parameters for all welding process-
es to their factory settings
Resetting of the selected value to its factory set-
ting must be confirmed by pressing the adjusting
dial.
Level 2 Setup menu
For setting general parameters
For details, see section "Level 2 Setup menu"
Description
Comfort Stop Sensitivity (Comfort Stop Sensi-
tivity)
Factory setting on TransPocket 150: 1.6 volts
Factory setting on TransPocket 180: 1.5 volts
For details, see section „TIG Comfort Stop"
Break voltage (U cut off)
Used to specify at which arc length the welding
process is completed.
The welding voltage increases as the length of the
arc increases. The arc is extinguished when it
reaches the voltage specified here
Factory setting: 15 volts
Range
Unit
25 - 90 Volts
No
YES
ALL
Range
Unit
OFF
Volts
0.5 - 2.5
12 - 22 Volts