Technical data

Explanation of
Duty cycle (D.C.) is the proportion of time in a 10-minute cycle at which the device may be
the term "duty cy-
operated at its rated output without overheating.
cle"
The D.
C. values specified on the rating plate are based on an ambient temperature of 40°C. If the
ambient temperature is higher, either the D.C. or output must be reduced accordingly.
Example: Welding at 150 A at 60% D.C.
-
-
-
If the device is to be continuously operated without stopping:
1
2
48
NOTE!
Welding phase = 60% of 10 minutes = 6 minutes
Cooling phase = remaining time = 4 minutes
After the cooling phase, the cycle begins anew.
150 A
0 A
0 Min.
look in the technical data for a D.C. value of 100% for the reigning ambient tempera-
ture.
Reduce the output or amperage in line with this value so that the device can remain in
use without observing a cooling phase.
60 %
6 Min.
6 Min.
4 Min.
10 Min.