Specifications
Type designation
1)
High/Normal overload
Typical shaft output at 550 V (kW)
Typical shaft output at 690 V [kW]
Enclosure protection rating IP20
Enclosure protection rating IP21, IP55
Output current
Continuous (525-550V) [A]
Intermittent (60 s overload) (525-550V) [A]
Continuous (551-690V) [A]
Intermittent (60 s overload) (551-690V) [A]
continuous KVA (at 550 V) [KVA]
continuous KVA (at 690 V) [KVA]
Maximum input current
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 690 V) [A]
Intermittent (60 s overload) (at 690 V) [A]
Additional specifications
Maximum cable-cross section for mains
2
and motor [mm
] ([AWG])
Maximum cable cross-section for load
share and brake [mm
2
] ([AWG])
2)
Maximum cable cross-section
for mains
2
disconnect [mm
] ([AWG])
Estimated power loss
at rated maximum load [W]
3)
4)
Efficiency
Table 8.12 B4, C2, C3 Enclosure, Mains Supply 525-690 V IP20/IP21/IP55 - Chassis/NEMA1/NEMA 12 (FC 302 only), P30K-P75K
For fuse ratings, see chapter 8.7 Fuses and Circuit Breakers.
1) High overload=150% or 160% torque for a duration of 60 s. Normal overload=110% torque for a duration of 60 s.
2) The 3 values for the maximum cable cross-section are for single core, flexible wire and flexible wire with sleeve, respectively.
3) Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses may
increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to
www.danfoss.com/vltenergyefficiency
4) Efficiency measured at nominal current. For energy efficiency class see chapter 8.4 Ambient Conditions. For part load losses see
www.danfoss.com/vltenergyefficiency.
MG33AP02
Operating Instructions
P30K
P37K
HO
NO
HO
NO
22
30
30
37
30
37
37
45
B4
C3
C2
C2
36.0
43.0
43.0
54.0
54.0
47.3
64.5
59.4
34.0
41.0
41.0
52.0
51.0
45.1
61.5
57.2
34.3
41.0
41.0
51.4
40.6
49.0
49.0
62.1
36.0
49.0
49.0
59.0
54.0
53.9
72.0
64.9
36.0
48.0
48.0
58.0
54.0
52.8
72.0
63.8
95, 70, 70
(3/0, 2/0, 2/0)
600
740
740
900
0.98
0.98
Danfoss A/S © Rev. 07/2014 All rights reserved.
P45K
P55K
HO
NO
HO
NO
37
45
45
55
45
55
55
75
C3
D3h
C2
C2
54.0
65.0
65.0
87.0
81.0
71.5
97.5
95.7
52.0
62.0
62.0
83.0
78.0
68.2
93.0
91.3
51.4
61.9
61.9
82.9
62.1
74.1
74.1
99.2
59.0
71.0
71.0
87.0
87.0
78.1
105.0
95.7
58.0
70.0
70.0
86.0
87.0
77.0
105
94.6
150 (300 MCM)
95 (3/0)
185, 150, 120
(350 MCM, 300
MCM, 4/0)
900
1100
1100
1500
0.98
0.98
P75K
HO
NO
50
75
75
90
D3h
C2
87.0
105
130.5
115.5
83.0
100
124.5
110
82.9
100
99.2
119.5
87.0
99.0
129
108.9
-
-
-
-
8
8
-
1500
1800
0.98
59