The Runup; Measurement Control; The Set And Other Items; Run Up Measurement - Adash VA4 Pro II User Manual

Vibration analyzer
Table of Contents

Advertisement

ADASH
Adash 4400 – VA4Pro

The RunUp

Measurement Control

When you need to measure Run Up or Coast Down of the machines, then you should use the RunUp mode. It
enables the same measurements as in Analyzer mode, but controlled by speed, time or uncontrolled.
What does it mean "controlled"? In Analyzer mode you can measure the Set and then you have to save
measurements manually.
The RunUp is different. The measurements are saved automatically and additionally the measurements are
regularly repeated under the control. The trigger function is used for that control. The menu item Global/
Trigger Settings/ RunUp mode is used for setting.
Usually the speed is used for that control and new measurement is made, when the speed changes from
previous measurement of defined value (e.g.10 RPM).
Also the time can be used to control that procedure. Then you can take the measurement in defined time
interval ( e.g. each 60 sec ).
The asap is the next choice. It means no delay between measurements - As Soon As Possible. Be careful for
such mode. You can use all memory quickly.
The last choice is the Manual mode. You can press the Start button at any suitable moment to make a new
measurement.
The ending of run up is usually made manually by pushing STOP button.
The information about used and free memory is displayed during the measurement ( e.g. 5 / 103.2GB).

The Set and other items

The meaning of the Set and also meaning of other items in the RunUp menu are the same as in the Analyzer
mode.

Run up measurement

For example we define only one measurement in set. The proximity sensor on channel 1 is used.
The RunUp mode is set to speed and the value is 1Hz.
Start measurement - push Start button. After the full speed is achieved press STOP.
97
For further technical and contact information visit
www.adash.com
or email: info@adash.com