ADASH
Adash 4400 – VA4Pro
The balancing mass will be recalculated (split) into two required angles.
Select Balancer / Set Default Angle to return back to the original calculation.
If the number of blades was defined, the final mass is divided between the two nearest blades. The blade
number is always counted from the position of the trial mass. It means the trial mass is mounted to blade
number one.
You can select other blades in case when you cannot mount weight to the nearest blade (blades). Select
Balancer / Change Blades menu item.
89
For further technical and contact information visit
www.adash.com
or email: info@adash.com