Appearance - Adash VA4 Pro II User Manual

Vibration analyzer
Table of Contents

Advertisement

ADASH
Frequency unit
Speed unit
Hz, RPM, CPS, CPM
Power/Line Frequency
Phase range
(-180, 180) , (0, 360)
Displayed Spectra in Cascade
cascade graph. It is not the number of measured spectra !
Date Format
yyyy/mm/dd
dd.mm.yy
mm/dd/yyyy
Language
ENG, CZE, .... select your language
Align Graphs on, off
function of all graphs can be aligned.
Graph Grid
on,off
Cursor Type
linear, maxs
axe) is displayed on the approx. 600 screen pixels. But the spectrum could have 25600 lines and then 42 lines
is displayed in one pixel line ( 42=25600/600). This number of lines in one graph pixel is different for other total
line number and used zoom. In the older VA4 version we used the cursor movement procedure by lines. It
means that the cursor moves inside one pixel without any real move on the screen. The users complained about
it. In the version 2 we have used another procedure. The cursor moves by pixels, not by lines. In each pixel is
hidden more lines and the cursor must display one specific line. What line should we use? When the Cursor
type is set to linear, then the step of cursor movement is the number of lines in one pixel. When the maxs is set,
then the cursor is always move to the maximum line, which is contained in one pixel.
Record analysis speed
suppose the record length is 300 sec, it could be e.g. run up record. You want to measure the 1x amp+phase
(ampl+phase+speed) during the record. If you want to watch the continuous results, then select the real time
mode and the processing of record will take 300 sec (the analyzing time is the same time as the recording time
was). If you want to save results to the memory and not to watch them on the screen, then select fast mode.
The analyzing time will be much faster then 300 sec.
Record Analysis Start
selected for analysis.
It would be better to use example for explanation. E.g. we use record which length is 60 sec. We define time
signal measurement which length is 8 sec. It means when we push Start button, the reading takes 8 sec and
position of cursor moves of 8 sec in record.
continue
the next reading will start on the end of last reading
begin
the next reading will start on the beginning of record
again
the next reading will start on the beginning of last reading
ask
the user select any option before the reading
IMPORTANT : when you moved the cursor manually, the the next reading will always start from that position.

Appearance

Background Color
You can create your own colors profile. Use the create item below the black and white. The col.cpy will be
creted on VA4_DISC. You can change the RGB value of all colors and then save it with new name. When the
For further technical and contact information visit
Hz, RPM, CPS, CPM
it is used for Elect value in Synch table, which is displayed for spectra
the range of phase values
32, 128, 256, 512, 1024
the a.m./p.m. is used
if more graphs of the same type are displayed, then the Zoom and Cursor
this item must be deeply explained. The graph width (e.g.spectrum frequency
fast, real tíme
continue, begin, again, ask
black, white
the record could be analyzed in two ways. Let's
these options are used when the record is
setting of background and other colors.
35
www.adash.com
Adash 4400 – VA4Pro
the number of displayed spectra in
or email: info@adash.com