Full Spectrum - Adash VA4 Pro II User Manual

Vibration analyzer
Table of Contents

Advertisement

ADASH
Adash 4400 – VA4Pro

Full spectrum

Set Full Spectrum to yes. Remember to set correct angles of both sensors. It influences the calculation. The
FFT is applied to complex signal, first channel is real part and second channel is imaginary part.
Note: Cursor is displayed on both sides. Different colors are used. Both cursor values are displayed.
Attention!
The correct setting of channel A and B is critical for correct result. If this setting is wrong then the
negative and positive side are interchanged. Firstly we find the angle between A and B, which is less
then 180° (usually it is 90°). The rotation mark must be firstly on A and then in B.
65
For further technical and contact information visit
www.adash.com
or email: info@adash.com