spectrum 200 hz
FFT spectrum of velocity in the 200 Hz range.
The speed frequency line is displayed white (if it is known).
Three top peaks are displayed in the list.
Time signal for roller bearing diagnosis
The acceleration time waveform filtered in 0.5 - 16 kHz band-
pass. It means the speed frequency and harmonic frequencies of
the speed are removed.
The acceleration Demod - g
RMS value is displayed on the bottom.
ENV
www.adash.com
AdAsh 4900 - Vibrio M