Control Of Thightness - SCHUNK TANDEM KSF plus Series Assembly And Operating Manual

Table of Contents

Advertisement

9.2

Control of thightness

• The following components are required to check for leaks:
pressure gauge, pneumatic fitting, supply line and quick
coupler.
• Check for leaks with the clamping block in the CLOSED position.
Proceed as follows:
1 Connect the following sequence of parts to the connection in
the OPEN (I) position: pressure gauge, pneumatic fitting, supply
line with fast coupler.
2 Apply compressed air to the clamping block.
3 Close the shut-off valve and remove the supply line.
If the clamping system is leaking, check the screws first (e.g. with
Metaflux leak detection spray). Seal any leaking screws.
If the screw fastenings are tight, check the seals and replace if
necessary.
( 9.1, Page
Maintenance and care
23).