Installation recommendation for partial integration:

• The cover (part 5) is built into the table top via a mounting- or
through-hole.
• Compressed air is supplied to the base-side air connection »III«
on the clamping block by a hose line with a pneumatic plug-in
connection that is built into the opening in the cover (item 5)
below the table top.
• Do not open the frontal connection »I« of the clamping block,
or seal it airtight with a suitable dummy plug (M5 or G1/8").
• Before mounting the clamping block on the table top, unscrew
the Torx setscrew (item 23) at the base-side air connection »III«
in the cover (item 5) and replace it with the screw-in union with
the M5 connection thread.
NOTE:
• Screw the clamping block onto the machine table or the device.
Observe the screw tightening torques in doing so
( 6, Page
15).
• For the different ways to mount the clamping block, see the
chapter on "Mounting the clamping block on the machine
table"
( 7.1, Page
• Before commissioning the clamping block, ensure that the
frontal pneumatic connection »I« is properly sealed.
• The assembly parts (screws, clamping sleeves) are included in
the accessory pack. The recommended plug-in connections are
not delivered with the clamping block.

Installation recommendation for complete installation:

• The cover (item 5) is built into the table top via a mounting
hole.
• Compressed air is supplied to the air connection »III« at the
base of the clamping block by a hose-free direct connection in
the machine table. The base-side opening is sealed with an O-
ring for this purpose.
• The cylindrical mounting hole should be drilled + 0.1 to + 0.4
mm wider than the Ø »U« of the clamping block.
• Exact compliance with the specified mounting depth of the
cover (item 5) is essential. The mounting depth is determined
by the dimension »T« and must be finished to a tolerance of +
0.1 to + 0.3 mm (see "Technical data"
15).
( 5, Page
12)).