DEMA CPM 310 G User Manual page 222

Digital overcurrent protection relay
Table of Contents

Advertisement

H
-
I
%(I
/I
)>
Broken conductor protection function. / Instantaneous tripping due to broken conductor
2
1
protection. / Broken conductor protection threshold value.
I<
Undercurrent protection function. / Instantaneous tripping due to undercurrent protection. /
Undercurrent protection threshold value.
I>
Phase overcurrent 1
overcurrent 1
I>>
Phase overcurrent 2
overcurrent 2
I>>>
Phase overcurrent 3
overcurrent 3
I
>
Earth overcurrent 1
e
overcurrent 1
I
>>
Earth overcurrent 2
e
overcurrent 2
I
>>>
Earth overcurrent 3
e
overcurrent 3
I
Nominal current.
n
I
Rated current.
r
I
Set / threshold current.
s
I
>
Thermal overload protection.
θ
I
>
Negative sequence overcurrent 1
2
due to negative sequence overcurrent 1
overcurrent protection 1
I
>>
Negative sequence overcurrent 2
2
due to negative sequence overcurrent 2
overcurrent protection 2
IDMT
Inverse Definite Minimum Time.
IEC
International Electro-technical Commission.
IEEE
Institute of Electrical and Electronics Engineers, U.S.A.
IP
International Protection Rating according to IEC 60529 Standard.
IP20
Protection against objects with size >12.5mm.
IP52
Protection against dust and dripping water when tilted up 15°.
ISO
International Organization for Standardization.
J
-
K
-
L
L5
Programmable LED no.5.
L6
Programmable LED no.6.
L7
Programmable LED no.7.
L8
Programmable LED no.8.
L9
Programmable LED no.9.
L10
Programmable LED no.10.
L11
Programmable LED no.11.
L12
Programmable LED no.12.
Latch
Relay locking.
st
threshold protection function. / Instantaneous tripping due to phase
st
threshold protection. / Phase overcurrent protection 1
nd
threshold protection function. / Instantaneous tripping due to phase
nd
threshold protection. / Phase overcurrent protection 2
rd
threshold protection function. / Instantaneous tripping due to phase
rd
threshold protection. / Phase overcurrent protection 3
st
threshold protection function. / Instantaneous tripping due to earth
st
threshold protection. / Earth overcurrent protection 1
nd
threshold protection function. / Instantaneous tripping due to earth
nd
threshold protection. / Earth overcurrent protection 2
rd
threshold protection function. / Instantaneous tripping due to earth
rd
threshold protection. / Earth overcurrent protection 3
st
threshold protection function. / Instantaneous tripping
st
threshold value.
nd
threshold protection function. / Instantaneous tripping
nd
threshold value.
- 222 -
st
threshold protection. / Negative sequence
nd
threshold protection. / Negative sequence
st
threshold value.
nd
threshold value.
rd
threshold value.
st
threshold value.
nd
threshold value.
rd
threshold value.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents