4-3 Commands and Responses during CR Control
3) Write identical data
Use this command to write identical data to tags by the page. Data is written to user-specified pages.
This command is useful when writing the same data to multiple pages (specification is required only
once).
There is no need to perform the verify read process, since this command performs it as part of its
execution.
Command
As parameters, the command sends specification of the pages to be written and the data to write to the
specified pages one page at a time. The page specification is as follows: The bits that correspond to the
pages to be written are set to 1, and all other bits are set to 0. This binary number is converted to
hexadecimal and sent with the command. Specify the write data sequentially in ascending order of the
pages specified. In the case of a Tag equipped with I-CODE1, specify the write data in the order:
F⇒0⇒1⇒···⇒A.
Command
' 0 '
' 3'
Bit
Page
Settable
Value
*1
Number of data n = Number of specified pages x 8 (hexadecimal)
Number of data n = Number of specified pages x 4 (ASCII)
Response
The response returns the end code (normal end: '00').
End code
' 0 '
' 0 '
Command Example
The following table gives details of tag user memory when executing the following command.
(1) Writing 30303030 hexadecimal to pages 8, 9, and 10 using FIFO Trigger Mode with hexadecimal:
Command '03 08 0700 30303030<CR>'
Response '00<CR>
4-22
Page specification
Communica-
(4 characters)
tions option
7
6
5
4
3
2
1
F E D
C B A 9
' 00' to ' 07 '
' 10' to ' 17 '
Page
Byte 0
0
30 Hex
1
34 Hex
2
38 Hex
3
40 Hex
4
44 Hex
5
48 Hex
6
4C Hex
7
50 Hex
8
30 Hex
9
30 Hex
10
30 Hex
Data 1
0
7
6
5
4
3
2
8
7
6
5
4
3
2
'00' to 'FF'
Byte 1
Byte 2
31 Hex
32 Hex
35 Hex
36 Hex
39 Hex
30 Hex
41 Hex
42 Hex
45 Hex
46 Hex
49 Hex
4A Hex
4D Hex
4E Hex
51 Hex
52 Hex
30 Hex
30 Hex
30 Hex
30 Hex
30 Hex
30 Hex
Write data*1
⋅⋅⋅⋅⋅⋅
1
0
1
0
Byte 3
33 Hex
37 Hex
30 Hex
43 Hex
47 Hex
4B Hex
4F Hex
53 Hex
30 Hex
30 Hex
30 Hex
Section 4-3
Data n