4-3 Commands and Responses during CR Control
4-3-4 Commands Specific to the I-CODE1 Chip
1) Read Serial Nnumber
Use this command to read tag serial numbers.
Command
Command
' 0 '
' 5 '
Response
The response returns the tag serial number read, and the end code (normal end: '00').
End code
' 0 '
' 0 '
The tag serial number is 16 digits in hexadecimal code.
2) Read Family Code and Application ID
Use this command to read tag family codes and application IDs.
Command
Command
' 0 '
' 6 '
Response
The response returns the tag family code, application ID read, and end code (normal end: '00').
End code
' 0 '
' 0 '
3) Write Family Code and Application ID
Use this command to set the tag family codes and application IDs.
Command
Command
' 0 '
' 7 '
Response
The response returns the end code (normal end: '00').
End code
' 0 '
' 0 '
4-18
Tag serial number
......
Data 1
Application
Family Code
ID
'00' to 'FF'
'00' to 'FF'
Application
Family Code
ID
'00' to 'FF'
'00' to 'FF'
Data n
Section 4-3