Commands Specific To The I-Codesli Chip - Omron V720 Series User Manual

Electromagnetic inductive rfid system, usb type rfid unit
Hide thumbs Also See for V720 Series:
Table of Contents

Advertisement

4-3 Commands and Responses during CR Control
 

4-3-3 Commands Specific to the I-CODESLI Chip

1) Write, Lock AFI
Use this command to change or lock tag AFI.
Command
Command 
' 3 '  ' 6 ' 
Response
The response returns the end code (normal end: '00').
End code 
' 0 ' 
' 0 ' 
2) Write, Lock DSFID
Use this command to change or lock tag DSFID.
Command
Command 
' 3 '  ' 7 ' 
Response
The response returns the end code (normal end: '00').
End code 
' 0 ' 
' 0 ' 
Communica-
Process
tions option 
option 
 
 
 
Process
 
option 
Write AFI 
01 Hex 
Lock AFI 
02 Hex 
Communica-
Process
tions option 
option 
 
 
 
Process
 
option 
Write DSFID 
01 Hex 
Lock DSFID 
02 Hex 
   
Data 
 
 
 
Data 
AFI = 00 to FF(Hex)
00 Hex 
Data 
 
 
 
Data 
AFI = 00 to FF(Hex)
00 Hex 
Section 4-3