5-5 Mutual Interference (Reference)
5-5
Mutual Interference (Reference)
If using multiple RFID Units near each other, keep a distance as shown below to prevent malfunction
due to mutual interference.
Parallel Antennas
Facing Antennas
Mutual interference depends on the operating environment of the RFID Unit and tags, so be
Note
sure to check the environment before operation.
5-10
100 mm or more
250 mm or more
Section 5-5