Agitator Operation
The AGITATOR OPERATION option allows the
Manager to select either continuous or intermittent
agitator operation.
Agitator operation may be set to operate in the
standard mode or "with Hopper Refrig." In the
standard mode, the agitator operates during AUTO,
STANDBY, and Heat Treat. In the "with Hopper
Refrig" mode, it runs only when the hopper is
refrigerating and during the Heat, Hold, and Soak
phases of a heat cycle and the Cool phase of a heat
cycle if the hopper is refrigerating. The default is
"standard" operation.
AGITATOR OPERATION
> Standard operation
with Hopper Refrig
Exit
Use the arrow keys to move to the desired operation
and touch the SEL key to accept the selection.
Mix Level Audible
The MIX LEVEL AUDIBLE option, when enabled,
will alert the operator with an audible tone when
there is Mix Low or Mix Out condition. The following
screen is displayed upon selecting this option.
MIX LEVEL AUDIBLE
ENABLED
> Enable
Disable
Disable the audible tone feature by touching the
DOWN arrow key to move the arrow to "Disable".
Touch the SEL key to save the new setting and
return to the Menu. The control panel icons for Mix
Low and Mix Out will illuminate as the mix level
drops in the hopper, but the audible tone will be
disabled.
150408
Important: To the Operator
Fault Description
The Fault Description screen will indicate if there is a
fault with the freezer and where the fault occurred.
When no faults are detected, the following screen
will be displayed.
FAULT DESCRIPTION
NO FAULT FOUND
Touch the SEL key to display the next fault found or
return to the Manager Menu if no other faults exist.
Touching the SEL key any time faults are displayed
will clear the faults, if corrected, upon returning to
the Menu screen.
Listed below are the variable messages which will
appear, along with an explanation for the corrective
action.
NO FAULT FOUND - There was no fault found in
the freezer. Nothing will appear on the screen after
this variable message appears.
BEATER OVERLOAD - Place the power switch in
the OFF position. Wait 5 minutes for the machine to
cool. Press the beater reset button firmly. Place the
power switch in the ON position and restart in
AUTO.
COMPRESSOR HPCO - Place the power switch in
the OFF position. Wait 5 minutes for the machine to
cool. Place the power switch in the ON position and
restart in AUTO.
HOPPER THERMISTOR FAIL* - Place the power
switch in the OFF position. Call service technician.
BARREL THERMISTOR FAIL* - Place the power
switch in the OFF position. Call service technician.
*Note: Three codes have been set up to assist in
diagnosing bad thermistor probes. If a probe has
shorted (resistance less than 1 ohm), "SHRT" will
display for its respective machine location. If the
probe is open (resistance above 1 megohm),
"OPEN" will display. If the actual probe environment
exceeds 200°F (93°C), the respective screen display
location will read "OVER", indicating the temperature
is "out of range".
COMP ON TOO LONG - The compressor run time
exceeded the 11 minute timer.
28
Models C708 & C716