ZIEHL-ABEGG Fcontrol FKDMxx-C Series Operating Instructions Manual
ZIEHL-ABEGG Fcontrol FKDMxx-C Series Operating Instructions Manual

ZIEHL-ABEGG Fcontrol FKDMxx-C Series Operating Instructions Manual

Frequency inverter with integrated sine filter for 3 - compressor motors in refrigeration technology
Table of Contents

Advertisement

Quick Links

english
Fcontrol
FKDM..-C
Frequency inverter with integrated sine lter for 3 ~ compressor
motors in refrigeration technology
Operating Instructions
Software version: D1553A from Version 2.38
L-BAL-E057-GB 1304 Index 009
Part.-No. 00163327-GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fcontrol FKDMxx-C Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ZIEHL-ABEGG Fcontrol FKDMxx-C Series

  • Page 1 english Fcontrol FKDM..-C Frequency inverter with integrated sine lter for 3 ~ compressor motors in refrigeration technology Operating Instructions Software version: D1553A from Version 2.38 L-BAL-E057-GB 1304 Index 009 Part.-No. 00163327-GB...
  • Page 2: Table Of Contents

    Operating Instructions Fcontrol – model series FKDM..-C Content General notes ............. Structure of the operating instructions .
  • Page 3 Operating Instructions Fcontrol – model series FKDM..-C 5.13.1 Networking via MODBUS-RTU ........5.13.2 RS-485 - network design and interface parameter .
  • Page 4 Operating Instructions Fcontrol – model series FKDM..-C 9.6.2.10 Reset, Function ........9.6.2.11 Setting Max.
  • Page 5: General Notes

    We do not accept any liability for possible errors or omissions in the information contained in data, illustrations or drawings provided. Ziehl-Abegg AG is not liable for damage due to misuse, incorrect use, improper use or as a consequence of unauthorized repairs or modifications.
  • Page 6: Product Safety

    Operating Instructions Fcontrol – model series FKDM..-C Safety instructions Danger due to electric current Warning of dangerous voltage or dangerous current. Information Important additional information and advice for user. Product safety The device conforms to the state of the art at the time of delivery and is fundamentally considered to be reliable.
  • Page 7: Modifications / Interventions In The Device

    There is no guarantee that parts from non-original sources are designed and manufactured in correspondence with load and safety requirements. Parts and optional equipment not supplied by Ziehl-Abegg are not approved by Ziehl-Abegg for use. Operator’s obligation of diligence •...
  • Page 8: Product Overview

    Operating Instructions Fcontrol – model series FKDM..-C Product overview 3 Product overview Operational area Fcontrol model series FKDM..-C are designed for a steplesss control of 3 ~ compressor motors Constant pressure and temperature trend, caused by the continiously compressor power control, makes energy saving at the most energy-intensive part of the refrigeration circuit possible.
  • Page 9: Mounting

    Operating Instructions Fcontrol – model series FKDM..-C Mounting 4 Mounting General notes Attention! The following points must be complied with during the mechanical installation to avoid causing a defect in the device due to assembly errors or environmental influences: • Before installation remove the device from the packing and check for any possible shipping damage! •...
  • Page 10: Electrical Installation

    Operating Instructions Fcontrol – model series FKDM..-C Electrical installation 5 Electrical installation Safety precautions Danger due to electric current • Work on electric components may only be carried out by trained electricians or by persons instructed in electricity under the supervision of an electrician in accordance with electrical engineering regulations.
  • Page 11: Mains Connection

    Operating Instructions Fcontrol – model series FKDM..-C Electrical installation 5.2.4 Harmonics current and line impedance for devices > 16 A and ≤ 75 A Extract from EN 61000-3-12, valid for equipments with rated current > 16 A and ≤ 75 A, connected to public low-voltage systems.
  • Page 12: Inverter Output

    Operating Instructions Fcontrol – model series FKDM..-C Electrical installation Inverter output 5.5.1 Motor connection The motor leads are connected to the terminals: PE, U, V, W. Comply with the motor data (rating plate) regarding the type of connection (Y or D). Adjustments in line with the motor in question can be carried out in “Motor Setup”.
  • Page 13: Output Voltage 0 - 10 V (Analog Out)

    Operating Instructions Fcontrol – model series FKDM..-C Electrical installation When triggering with a PWM signal (10 V) the ratio between the pull-up resistor and the internal resistance of the open collector output must be considered. Attention! Never apply line voltage to analog inputs! Output voltage 0 - 10 V (Analog Out) IO Setup: Analog output “A”).
  • Page 14: Communication

    Operating Instructions Fcontrol – model series FKDM..-C Electrical installation 5.13 Communication 5.13.1 Networking via MODBUS-RTU The device comes equipped with a RS-485 interface for networking via MODBUS. Conntection at: “A (D+)”, “B (D-)” and “GND”. The address must be set in the “IO Setup” menu. Information A maximum of 64 members can be directly connected to one another, and another 63 members via a repeater.
  • Page 15: Lon Bus System Is Possible Via Add-On Module

    Operating Instructions Fcontrol – model series FKDM..-C Electrical installation Information If any matters are unclear, please contact our V-STE support department for control systems - ventilation technology. The information sheet "Network structure of MODBUS" R-TIL08_01 contains detailed information about "MODBUS". ®...
  • Page 16: Controls And Menu

    Operating Instructions Fcontrol – model series FKDM..-C Controls and Menu 6 Controls and Menu Multipurpose LC display and keyboard 6 7 8 27.11.2008 v_display_erklaerung_fcontrol_c.vsd 1. Numeric display 5 digit Program key and open menu 2. Moon-Symbol for set point 2 Menu selection, reduce value ▼...
  • Page 17: Menu Operation

    Operating Instructions Fcontrol – model series FKDM..-C Controls and Menu Menu operation Display after turning on the mains voltage. description for menu language English = “GB” (delivery status). Switch-over between * actual value and “Start” with the key shortcut for Escape ((Esc = ▼...
  • Page 18: Example For Programming Mode 1.11 In "Base Setup

    Operating Instructions Fcontrol – model series FKDM..-C Controls and Menu Selection of the menu group (e.g. Base setup) to the right through the ▼-key, to the left through the ▼-key. You can go to the menu items in the menu groups (e.g. mode of operation) by using the P key. Use the arrow keys to move up and down within the menu group.
  • Page 19: Base Setup

    Operating Instructions Fcontrol – model series FKDM..-C Base setup 7 Base setup Jumper for input signal Factory setting of internal jumper in position “V” for 0 - 10 Signal. For sensors with 4 - 20 mA postion must be changed to “mA”. The sensor measuring range takes place in the basic setting of the mode in question ( Programming).
  • Page 20: Select Operation Mode

    Operating Instructions Fcontrol – model series FKDM..-C Base setup Select operation mode Information Simple installation is possible through the selection of the preprogrammed mode of operation. This determines the basic function of the device. Factory setting 1.10 = speed controller with maximum output frequency 50 Hz (setting by 0 - 10 V signal).
  • Page 21: Start-Up

    Operating Instructions Fcontrol – model series FKDM..-C Start-up 8 Start-up Prerequisites for commissioning Attention! 1. You must mount and connect the device in accordance with the operating instructions. 2. Double check that all connections are correct. 3. The mains voltage must match the information on the rating plate. 4.
  • Page 22: Menu Overview Mode (Without Add-On Modules)

    Operating Instructions Fcontrol – model series FKDM..-C Programming “Start” Switch Motor to ON in menu group ▲ Menu overview Mode 1.01 (without add-on modules) Base Controller Motor Start Info Setting Events IO Setup Limits Diagnostic setup Setup Setup 4.0 A 25.0 Hz 50.0 Hz 1.10...
  • Page 23: Setting For Operation Modes 1.10

    Operating Instructions Fcontrol – model series FKDM..-C Programming Base setup Base setup E2 Analog In As long as no allocation has been carried out display: - - - - - Selection: 0 - 20 mA, 4 - 20 mA, Bus (Inverting IO Setup) E2 Analog In Factory setting: 0 - 10 V...
  • Page 24 Operating Instructions Fcontrol – model series FKDM..-C Programming Diagram setting signal and output frequency [Hz] n-min 10 Hz n-max. = 50 Hz n-min 20 Hz n-max. = 45 Hz n-min OFF n-max. = 50 Hz = 5 Hz = 6 Hz Analog In 1 0...10 V 0...20 mA...
  • Page 25: Menu Speed Controller 1.10

    Operating Instructions Fcontrol – model series FKDM..-C Programming 1.10 1.11 9.1.3 Menu Speed controller Parameter Factory setting User Setting Start Motor PIN input - - - - - - - - - - Language Reset Mode 1.10 1.11 Fcontrol-C 2.38 2.38 d 1334 B07 07/17/09...
  • Page 26 Operating Instructions Fcontrol – model series FKDM..-C Programming Parameter Factory setting User Setting IO Setup A Function A min. 0.0 V 0.0 V A max. 10.0 V 10.0 V A Inverting A2* Function A2* min. 0.0 V 0.0 V A2* max. 10.0 V 10.0 V A / A2 Function...
  • Page 27 Operating Instructions Fcontrol – model series FKDM..-C Programming Parameter Factory setting User Setting Lmt E1 Function Lmt E1 min - - - - - - - - Lmt E1 max. - - - - - - - - Lmt E1 Hyst. - - - - - - - - Lmt E1 Del.
  • Page 28: Back Pressure Regulation 3.10

    Operating Instructions Fcontrol – model series FKDM..-C Programming Back pressure regulation 3.10 3.11 3.20 3.21 3.10 3.11 3.20 3.21 9.2.1 Base setup Base setup Base setup Mode Mode selection e.g. 3.10 Mode E1 Analog In For all Modes in Group 3 ( 3.10 3.11 3.20...
  • Page 29: Setting For Operation Modes 3.10

    Operating Instructions Fcontrol – model series FKDM..-C Programming 3.10 3.11 3.20 3.21 9.2.2 Setting for operation modes Back pressure regulation 3.10 Maximal output frequency 50 Hz Back pressure regulation 3.11 Maximal output frequency 87 Hz Back pressure regulation with input for refrigerant 3.20 Maximal output frequency 50 Hz Back pressure regulation with input for refrigerant...
  • Page 30: Functional Diagrams Back Pressure Regulation

    Operating Instructions Fcontrol – model series FKDM..-C Programming Manual mode “OFF” = automatic control as function of the set parameters (Factory setting) “ON” = automatic control without function, speed setting in menu “Speed manual” Manual mode Speed Manual mode Activation through “Manual mode” menu or external contact on digital input. Switchover takes place via a floating contact.
  • Page 31: Menus For Back Pressure Regulation 3.10

    Operating Instructions Fcontrol – model series FKDM..-C Programming Functional diagrams for Mode 3.20 (Idealized principle diagram) 100 % Min. 0 % Max. = 100 % 50 % 6 °C 16 K -10 °C 28.11.2008 v_diagramm_320_c.vsd nM Motor speed S Setpoint R Pband I Actual value Information...
  • Page 32 Operating Instructions Fcontrol – model series FKDM..-C Programming Parameter Factory setting User Setting Setting Setpoint1 - 10.0 °C - 10.0 °C 1.00 bar 1.00 bar Setpoint2 - - - - - - - - - - - - - - - - Pband 3.00 bar 3.00 bar...
  • Page 33 Operating Instructions Fcontrol – model series FKDM..-C Programming Parameter Factory setting User Setting 50 % 50 % 50 % 50 % 50 % 50 % 50 % 50 % IO Setup A Function A min. 0.0 V 0.0 V 0.0 V 0.0 V A max.
  • Page 34 Operating Instructions Fcontrol – model series FKDM..-C Programming Parameter Factory setting User Setting Level. Function Level min. - - - - - - - - - - - - - - - - Level max. - - - - - - - - - - - - - - - - Level Delay...
  • Page 35: Menu Group Start

    Operating Instructions Fcontrol – model series FKDM..-C Programming Menu group Start Start Start Motor (Menu dependent on device type available) In this menu point the modulation for the motor can be switched on and off (ON / OFF). Factory setting to , this prevents the system from inadvertently starting up before configuration is complete.
  • Page 36: Menu Group Info

    Operating Instructions Fcontrol – model series FKDM..-C Programming Menu group Info Menu group Info Info Info for mode speed controller 1.10 1.11 Inverter output frequency. Frequency Display of motor current (Metering precision approx. +/-10%) Motor current Display of the currently active default signal. The percentage corresponds to the internal actuation of the power component under consideration of the settings “Min.
  • Page 37: Controller Setup

    Operating Instructions Fcontrol – model series FKDM..-C Programming Controller Setup 9.5.1 PIN protection activate, PIN 0010 The adjustments for the installation in the service level can be protected against unintentional modifications. To do this, activate the “PIN protection” = “ON”. In order to simplify the initial start-up operation, the service level in the factory setting is PIN Protection free = “OFF”...
  • Page 38: Limit

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.5.5 Limit After allocation of a digital input ( IO Setup) an adjustable limitation of the modulation can be activated via a digital input (“D1”, “D2”, ..). As long as no allocation has been carried out “IO Setup”. Display: - - - - Limit “Limit value”...
  • Page 39: Group Control

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.5.7 Group control 9.5.7.1 Control group 2 via 0 - 10 V output Group 2 ON value Switch-on value for Group2 Setting range: 0 - 100 % Group 2 ON value Factory setting: 50 % * OFF Value Group2 Switch-off value for group2 Setting range: 0 - 100 %...
  • Page 40: Control Group 2/3/4 Via Relais

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.5.7.2 Control group 2/3/4 via relais Group 2 ON value Switch-on value for Group2 Setting range: 0 - 100 % Group 2 ON value Factory setting: 50 % * OFF Value Group2 Switch-off value for group2 Setting range: 0 - 100 % OFF Value Group2...
  • Page 41: Reverse Action Of The Control Function

    Operating Instructions Fcontrol – model series FKDM..-C Programming Example: Activation of 3 groups via relays G3 ON = 70 % G2 ON = 50 % G4 ON = 85 % Controller Fout Standard Master 0 ...100 % Digital Out Z-Modul-B Analog Signal OFF = 0 %...
  • Page 42: Controller Configuration

    Operating Instructions Fcontrol – model series FKDM..-C Programming Example of modes with input for refrigerant 100 % 10.05.2007 v_umkehr_regelfunktion.vsd (idealized principle diagram) nM Motor speed R Pband S Setpoint I Actual value OFF for Val>Set = n+ ON for Val>Set = n+ 9.5.9 Controller configuration The “controller configuration”...
  • Page 43: Data On The Total Control Deviation

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.5.10 Data on the total control deviation The total control deviation is comprised of the sum of the control deviations for performance quantities and work quantities combined and refers to the specified areas. In direct reference to the acquired input and controlled variables, the maximum deviation to the target value is <...
  • Page 44: Digital Inputs "D1" / "D2

    Operating Instructions Fcontrol – model series FKDM..-C Programming A1 Function “A min.” and “A max.” A1 Function Analog 10 V 10 V A max: 10 – 5V A min: 0 – 5V Funktion Signal 100 0 -100 % 0 – 10 V 16.03.2007 10 –...
  • Page 45: Enable On/Off Function | 1D

    Operating Instructions Fcontrol – model series FKDM..-C Programming For modes as controller higher 3.10 3.21 Switch over “Setpoint1” / “Setpoint2” Switch over “Intern” / “Extern” Switch over “Control” / “Manual mode”(factory setting for “D2”) Switch over control function “Reset” Setting Max. Speed “ON” / “OFF” Motorheating ON / OFF Switch over direction of rotation “right”...
  • Page 46: Limit On / Off, Function

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.6.2.4 Limit ON / OFF, Function The value for “Limit” adjusted in the Controller Setup, is activated over a digital input. Contact at digital input e.g. “Digital In 1”. For “D1” Inverting“OFF”, limitation active at closed contact. - - - - - Controller n = 0- 80 %...
  • Page 47: Intern / Extern Function | 6D

    Operating Instructions Fcontrol – model series FKDM..-C Programming Switch over between “Setpoint1” and “Setpoint2” (for modes as controller higher 3.10 Contact at digital input e.g. “Digital In 1”. • “D1 Inverting” “OFF” “Setpoint1” “Setpoint2” 18 °C at opened contact / 25 °C at closed contact.
  • Page 48: Automatic Control / Speed Manual Function | 7D | (Mode 3.10 )

    Operating Instructions Fcontrol – model series FKDM..-C Programming 3.10 9.6.2.8 Automatic control / speed manual Function (mode Factory setting for digital input “D2”. Switch over between automatic control to set target value (depending on the activation: “Setpoint1”, “Setpoint2”) and the default for “manual operation” set at the device. If for input 2 “E2 Function”...
  • Page 49: Setting Max. Speed On / Off Function

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.6.2.11 Setting Max. Speed ON / OFF function The value for “Max Speed” adjusted in menu “Settings”, is activated over a digital input. I.e. the unit works independently of the controller function firm with this value. Contact at digital input e.g.
  • Page 50: Direction Of Rotation, Function | 13D

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.6.2.13 Direction of rotation, Function Switch over “clockwise” rotation and “counterclockwise” rotation. When switching over via a digital input, the device works with the opposite function than the one set in motorsetup. Information If the rotary direction is reversed with an available modulation, it is initially reduced to “0”...
  • Page 51 Operating Instructions Fcontrol – model series FKDM..-C Programming E2 max. Setting range: 0 - 100 % Factory setting: 100 % E1 max. “1.01” Example for Mode with speed setting signal 0 - 10 V Modus 1 Modus 1 Example: “E1 min.” = 20 % [Hz] The controller begins only at approx.
  • Page 52: Inverting Analog Inputs "E1" / "E2

    Operating Instructions Fcontrol – model series FKDM..-C Programming “E1” “E2” 9.6.3.2 Inverting analog inputs After programming the signal or sensor type, an inversion of the inputs can be carried out. Factory setting for Inverting inputs = “OFF” (if input activated) (signal: 0 - 10 V, 0 - 20 mA, 4 - 20 mA).
  • Page 53: Programming Add-On Module Type Z-Modul-B

    Operating Instructions Fcontrol – model series FKDM..-C Programming Function Description No function Relays remain always de-energized Operating indication (factory setting for “K1”, non inverting). Operation without fault, reports enable “OFF” Fault indication (factory setting for “K2”, non inverting). Energized for operation without fault, for enable “OFF” not energized. De-energized at line, motor and controller fault, Sensor fault dependent on programming, external fault at digital input.
  • Page 54: Networking Via Modbus

    Operating Instructions Fcontrol – model series FKDM..-C Programming • 1 x output 0 - 10 V (A2 / GND), Function programmable, e.g., for: Fixed voltage, proportional level control, proportional input signal, group control, drive 2. • 3x digital inputs (D3 / GND, D4 / GND, D5 / GND) function programmable, e.g.: Enable (ON / OFF), external malfunction, output limitation, input 1/2, target value 1/2, internal/external preset, controller / manual operation, control-function reversal (“heating”...
  • Page 55: Limits

    Operating Instructions Fcontrol – model series FKDM..-C Programming Limits Menu group Limits Limits 9.7.1 Limit indication depending on modulation Following functions can be allocated to the limit indication without function Indication with the centralized fault of a programmed relay (IO allocation Level.
  • Page 56: Limit Indication Depending On Setting Or Sensor Signal

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.7.2 Limit indication depending on setting or sensor signal Following functions can be allocated to the limit indication without function Indication with the centralized fault of a programmed relay (IO allocation Lmt E1 Function Function Warning symbol in display, “AL”...
  • Page 57: Limit Indication Depending On (Offset) To Setpoint

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.7.3 Limit indication depending on (offset) to Setpoint In operating modes as a controller (via 3.10 ), two limit indicators can be carried out based on the set target value (Setpoint) and measured actual value (on E1). Following functions can be allocated to the limit indication without function Indication with the centralized fault of a programmed relay (IO allocation...
  • Page 58: Motor Setup

    Operating Instructions Fcontrol – model series FKDM..-C Programming Motor Setup Menu group Motor Setup Motor Setup 9.8.1 Setting motor rated current MotorRatedCurr. Setting for Motor rated current = setpoint of current controller (current limiting). Setting range: 0.0...device rated current / A MotorRatedCurr.
  • Page 59 Operating Instructions Fcontrol – model series FKDM..-C Programming = 50 Hz 100 % = 48.5 Hz edge = 10 % start [Hz] = 0 % start Analog In 1 0...10 V 0...20 mA 90 100 0...100 % PWM 03.08.2012 v_u_f_dia_fcontr_d_lin.vsd Uout Output voltage Ustart Start-up voltage Foff Shutdown Freq.
  • Page 60: Setting For Rampup Time And Rampdown Time

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.8.4 Setting for Rampup time and Rampdown time By separate menus for Rampup time and Rampdown time an adjustment is possible to individual system conditions. This function is switched behind the actual controller function. Rampup time Time setting in which the automatic controller output from 0 % to 100 % rises.
  • Page 61: Setting Brake Function

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.8.7 Setting brake function DC brake mode Setting function of DC-brake for frequency inverters. For units that come with a factory engaged DC brake mode (if extant, DC brake DC brake mode mode setting), simultaneously activating the “DC brake mode ”...
  • Page 62: Setting Derating Alarm And Temperaturemonitoring

    Operating Instructions Fcontrol – model series FKDM..-C Programming 9.8.9 Setting Derating Alarm and Temperaturemonitoring The device has integrated temperature monitoring to protect the device from damage caused by excessively high interior temperatures. In case of a temperature increase above the predetermined threshold value the level-control is linearly reduced until the stated threshold temperatures are reached.
  • Page 63: 10 Diagnostics Menu

    Operating Instructions Fcontrol – model series FKDM..-C Diagnostics menu 10 Diagnostics menu The diagnostics menu supplies information about the momentary operating condition of the device. Diagnostic O = Operation, T = Time, C = Controller The time counting runs, as soon as mains voltage is connected (without fault). If events step on (Motor fault, External Error, etc.), the period of operation is stored at 00056:46:13 this time (...
  • Page 64: Current Measurements

    Operating Instructions Fcontrol – model series FKDM..-C Events / Fault signals Status digital input 1 (Digital In 1) OFF = terminals D1 - D1 bridged ↔ ON = terminals D1 - D1 not bridged Status digital input 2 (Digital In 2) OFF = terminals D2 - D2 bridged ↔...
  • Page 65: Messages And Trouble Shooting

    Operating Instructions Fcontrol – model series FKDM..-C Events / Fault signals 1. Messages with code Message sensor fault for information, for Alarm sensor deactivated. Sensor 1 2. Alarms with code Events during which the device automatically restarts operation after the cause of the malfunction has been remedied (e.g. mains failure), or remains in operation (e.g.
  • Page 66 Operating Instructions Fcontrol – model series FKDM..-C Events / Fault signals Display Code* LED Code Relais switches Cause Reaction of Controller Opera- internal Fault Adjustment tion fault EEP damaged works with defaults EEP error EEP data incorrectly controller runs with the read settings EEP Corruption The device has integrated...
  • Page 67: 12 Software History

    Operating Instructions Fcontrol – model series FKDM..-C Software history Display Code* LED Code Relais switches Cause Reaction of Controller Opera- internal Fault Adjustment tion Device continues working un- selecta- Alarm from external con- changed tact check contacts External error Limit indication minimum selecta- Actual value below setting “Alarm Minimum”...
  • Page 68: 13 Enclosure

    Operating Instructions Fcontrol – model series FKDM..-C Enclosure 13 Enclosure 13.1 Technical data The name plate data for the rated current* output refer to a maximum ambient temperature of 40 °C. For higher temperatures note following position for operation with higher ambient temperature. Rated cur- Rated cur- max.
  • Page 69: Versions Type-Lines Fcontrol

    For devices > 16 A and ≤ 75 A according EN 61000-3-12 Electrical installation / harmonics current and line impedance) Please ask Ziehl-Abegg for the individual harmonic oscillation levels of the current as a percentage of the fundamental oscillation of the rated current.
  • Page 70: Connection Diagram

    Operating Instructions Fcontrol – model series FKDM..-C Enclosure 13.2 Connection diagram Fcontrol FKDM...AM(E)-C Kontaktbelastung Contact rating Adressierung max. AC 250 V 2 A Addressing TB/TP Digital Analog 24 V DC Analog Analog Digital Normal In 1* Out 1* In 1* In 2* In 2* GND TB/...
  • Page 71: Connection Suggestion For Bypass With Necessary Time Delay

    Operating Instructions Fcontrol – model series FKDM..-C Enclosure 13.2.1 Connection suggestion for Bypass with necessary time delay * Programming function enable (ON / OFF) necessary 13.3 Dimensions [mm] FKDM5/8/12 (FKDM18/22) (IP54) L-BAL-E057-GB 1304 Index 009 Part.-No. 00163327-GB 71/74...
  • Page 72 Operating Instructions Fcontrol – model series FKDM..-C Enclosure FKDM32...50 (IP54) FKDM32...50E (IP20) L-BAL-E057-GB 1304 Index 009 Part.-No. 00163327-GB 72/74...
  • Page 73 Operating Instructions Fcontrol – model series FKDM..-C 13.4 address Outdoor installation output voltage outputs 0 - 10 V Base setup bypass switching P-component pin code PIN input control cable PIN protection Current measurements current-operated protective devices Rampdown time Rampup time D-component rated current DC-brake...
  • Page 74: Manufacturer Reference

    Manufacturer reference Our products are manufactured in accordance with the relevant international regulations. If you have any questions concerning the use of our products or plan special uses, please contact: Ziehl-Abegg AG Heinz-Ziehl-Straße 74653 Künzelsau Telephone: +49 (0) 7940 16-0 Telefax: +49 (0) 7940 16-504 info@ziehl-abegg.de...

Table of Contents