General Information
2-6
Power Cord Information
A power cord with appropriate plug configuration is supplied with each
2212 Oscilloscope. Table 2-1 gives the color coding of the conductors in the
power cord. If you require a power cord other than the one supplied, refer
to Table
2-2:
Power Cord and Plug Identification
Table 2-1: Power Cord Conductor Identification
Conductor
Ungrounded (Line)
Grounded (Neutral)
Grounded (Earthing)
Operating Voltage
Color
Brown
Light Blue
Green/yellow
Alternate Color
Black
White
Green
This oscilloscope operates with a line voltage between 95-128 VAC and an
instrument line fuse of 1.0 A Slow Blow, or 190-250 VAC and an instru-
ment line fuse of 0.5 A Slow Blow, depending on the power-strap setting
inside the oscilloscope.