Appendix II: Maintenance

The Breakout box will require little in the way of routine maintenance, apart from
occasional routine checking of the fan outlets on the side panel.
Cleaning the casework should only be done with a cloth lightly dampened with
water only. The use of chemical cleaners may damage the paint finish or dissolve
printing!

Appendix III: Specifications

Connections:
Audio out: 8/16 x XLR or Phoenix
RS485 Comms Network I/O: 1 x XLR or Phoenix
GPI Port: 10 way mini-Phoenix
Network Audio Transport: 2 or 3 RJ45 (Ethernet)
Metering:
0dB LED threshold: +19dBu
Metering tolerance: +1.5dB
GPIO Port:
Inputs – 5V maximum (3V3 nominal)
Outputs – 3V3, 20mA
3V3 Output – 200mA max drain
Audio performance:
Sample Rate: 48kHz/96kHz (Dante only)
Maximum Output Level: +21.5dBu
Frequency Response: 20Hz–22kHz +0.5dB
Dynamic Range: > 112dB (Unweighted, 20Hz–20kHz)
Power supply requirements:
Voltage: 90-260V AC
Power consumption < 30W
Fuse rating: 1A
Dimensions:
482 x 428 x 88mm (WxDxH)
Weight:
Net weight: 3.5kg
Shipping weight: 5kg
2
MC
Audio reserve the right to change and improve the specifications without notice.