Remote Control and Monitoring

Overview

There are several methods of remote control available to the
Breakouts, allowing for various levels of system complexity. These may be
thought of as:
Remote Monitoring and Control On-line via RS485 and a PC with ICORE
Remote Monitoring and Control On-line via RS485/Ethernet and a PC with
ICORE
Remote Monitoring Off-line with an additional Breakout box in "Master
Mode" and an external control panel
When the PC isn't in use, the system can also be connected to a Breakout box in
"Master Mode" for off-line background monitoring, and all without reconfiguring
any cables!

Remote Control On-line via a Computer with ICORE

Breakouts can be connected, via their RS485 port, directly to a computer running
ICORE, allowing for configuration of their properties and adjustment of various
real time parameters.
RS485 data
control/monitor
LIMIT
A
SIGNAL
-6
POWER
COMMS
-12
-2
A/P
-20
0
2
2
MC
MC
LIMIT
A
SIGNAL
-6
POWER
COMMS
-12
-2
A/P
-20
0
2
2
MC
MC
LIMIT
A
SIGNAL
-6
POWER
COMMS
-12
-2
A/P
-20
0
2
2
MC
MC
Page 14
B
LIMIT
SIGNAL
-6
-12
-2
BRG
-20
0
Ti
NETWORK POWER AMPLIFIER
B
LIMIT
SIGNAL
-6
-12
-2
BRG
-20
0
Ti
NETWORK POWER AMPLIFIER
B
LIMIT
SIGNAL
-6
-12
-2
BRG
-20
0
Ti
NETWORK POWER AMPLIFIER
Ti Series
Network
audio link
INPUT
WARNING
COMMS
POWER
THIS EQUIPMENT
OUTPUT
FAILURE
TO LOCAL
AUDIO
MUST BE
AMPS ONLY
INPUT
EARTHED.
16
15
14
13
DO NOT EXPOSE
TO RAIN OR
MOISTURE.
8
7
6
5
90V-240V AC
50 - 60Hz 30W
RS485
LINE IN
CAUTION! SHOCK HAZARD. DO NOT REMOVE COVERS.
Laptop or desktop
running
iCORE
monitors and controls
all units on network
Breakout Operator's Manual
RJ45 CONNECTORS
A: PRIMARY/IN
ON LY FITTED
B: SECONDARY/OUT
FO R
12
11
10
9
ETH ERS O UN D
C: CONTROL
(ETHERSOUND)
1: NETWORK LOST
IDENTIFY
1 2 3 4 5 6 7 8 9 10
2: LOAD ERROR
3: PROTECT
4
3
2
1
4-6: GPIO 7: MUTE
2
8: LOCAL MASTER
MC
9: 3V3 / 10: GROUND
MANUFACTURED IN THE UK BY
Balanced
audio
OUTPUT
RS485 data
control/monitor
via USB-485 converter