MC2 Audio Ti Series Operator's Manual page 38

Breakouts
Hide thumbs Also See for Ti Series:
Table of Contents

Advertisement

The loader will start scanning for all connected devices to determine what unit it
has to update. After a few seconds the device will be found and identified (its
Power LED will begin to flash). Check the model number, which will be shown in
the status pane and if OK, press the "Load" button.
The Breakout will mute and power down immediately and the update will start.
DO NOT START ANY OTHER PROGRAMS DURING THE UPDATE!
DO NOT DISCONNECT THE BREAKOUT DURING THIS PROCEDURE!
During the update the RX and TX Comms LED will flicker. The update takes less
than 90 seconds and when complete, the Breakout will reboot automatically and a
message will confirm that the update is complete.
Remember that units cannot be updated over the audio transport bridge (i.e. via
another Breakout box over the Ethernet connection) and must be directly
connected to the local RS485 network from the computer.
Page 38
If there are multiple units to
update, then simply turn off the
completed one and switch on the
next one – ICORE will find it as
before. Press "Load" again to
update the unit.
Repeat this procedure for all units
as required.
Breakout Operator's Manual