Menu 3.5 Tank Gauge; General Info; Menu 3.5.1 Adjustment - Hardi HC5500 Instruction Book

Hide thumbs Also See for HC5500:
Table of Contents

Advertisement

7 - Menu 3 Calibration

Menu 3.5 Tank gauge

General info

This menu item is only present if the HARDI Tank Gauge is fitted. For increased accuracy it is recommended to do the flow
calibration [3.2] before proceeding.
Present accuracy is up to +/- 25 litre. This is at the widest liquid surface area in the tank. The smaller the liquid surface area,
the more accurate the readout. The accuracy is also affected of the sprayer being level. Assume the height of hitch point
measured from the ground should be 550 mm, then readout of tank contents changes with the hight of the sprayer at the
hitch point. In the schematic an example of the difference in tank contents can be seen.
Height at hitch eye
Actual content*
450 mm
500 mm
550 mm**
600 mm
650 mm
*known amount of water measured with a calibrated flowmeter.
**specified height.
***Displayed contents at correct hitch height.

Menu 3.5.1 Adjustment

The correction factor for the specific gravity of the liquid sprayed can be
set.
Default value is 1.000.
For liquid fertilisers, the specific gravity may range up to 1.3 kg/L. The
value in this case would be 1.300.
Method
1. Press
to change value.
2. Use
and
to move cursor to the figure to be changed.
3. Change figure by pressing
4. Repeat until all figures are correct. Confirm setting by pressing
44
COMMANDER 3200
2800 litre
2900 litre
2950 litre
2800 litre***
2750 litre
2700 litre
and
.
COMMANDER 4400
3900 litre
4000 litre
3950 litre
3900 litre***
3850 litre
3800 litre
3.5.1
TANK GAUGE
Adjustment
3.5.1.1
ADJUSTMENT
.
Spec. grav.
COMMANDER 6600
6000 litre
6100 litre
6050 litre
6000 litre***
5950 litre
5900 litre
X.XXX

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents