Checking Device Settings; Checking Measurement Input Values; Checking Output Signals; Checking Digital Communication (Modbus, Etc.) - Honeywell enCore FC Series Operating Instructions Manual

Flow computer
Table of Contents

Advertisement

7
7.2.1

Checking Device Settings

The legally relevant parameters can be checked in special device displays
( volume "Use in Legal Metrology" of the enCore FC manual). The enSuite
software will allow you to carry out a complete check of the current device
parametrization when the software has an online connection to the device.
7.2.2

Checking Measurement Input Values

Input measurements, in particular input values for flow conversion
(measurement data from gas meters, pressure transmitters, temperature
transmitters and, if applicable, gas composition measurement devices) can
be checked on the device display ( volume "Use in Legal Metrology" of the
enCore FC manual).
7.2.3

Checking Output Signals

Parameterized output signals can be measured using appropriate measure-
ment devices and checked in that way.
7.2.4

Checking Digital Communication (Modbus, etc.)

Appropriate tools (e.g. a protocol analyzer) can be used to check digital
communication.
7.2.5

Checking Measurements and Calculations

A final check of the accuracy of measurement results and calculations must
be executed when the device is used within the scope of legal metrology. A
metrology expert is required for this process, and the applicable legal regu-
lations must be observed.
7.2.6

End of Commissioning (from Basic System 03-24)

enSuite provides a convenient function to prepare an enCore flow computer
for operation at the end of commissioning. This function combines different
actions (e.g. the action Erase fiscal audit trail or Set counters) per stream.
enCore FC
Device Configuration and Commissioning
Operating Instructions