Input Channels - Honeywell enCore FC Series Operating Instructions Manual

Flow computer
Table of Contents

Advertisement

Technical Data

10.2 Input channels

ExMFE5 input
board
22
Burst mode is not supported by all transmitters.
Page 110 of 120
4 navigation and 2 function keys
2 multicolor LEDs for power and status
indication
sealable security switch
Table 7: General technical data
3 NAMUR inputs [Ex ib Gb] IIC for LF pulses
(max. 2 Hz, min. pulse length 200 ms) or HF
pulses (max. 5 kHz) or messages. One of
these inputs can alternatively be used for
connecting an encoder index.
analog input for a transmitter with 4 ... 20 mA
interface [Ex ib Gb] IIC, alternatively suitable
for connecting transmitters with HART interface
(1 transmitter in burst mode
mitters in multidrop mode)
input for Pt100 temperature transmitter in
4-wire technology, [Ex ib Gb] IIC
all inputs galvanically isolated amongst each
other, and inputs and system