Installation and Operating Instructions | idOil-30 3G, idOil-30 Battery 3G
4.
Settings
The settings of the idOil unit can be changed with the text message commands described in
the following paragraphs.
4.1.
Mobile numbers
Up to five telephone numbers can be programmed in the device, to which the unit can then
send alarm messages and from which it can receive settings and alarm status queries.
This setting can also be entered via the idOil unit's browser user interface.
4.1.1.
Setting telephone numbers and telephone number queries (TEL)
A total maximum of five numbers can be set 1–5 numbers at a time. The number is always
saved in the first free memory slot.
The format of the telephone number setting command is:
Field legend
TEL
<no1> <no2> <no3> <no4> <no5>
The device responds with a message including the name of the device (if set), the set
telephone numbers and the corresponding memory slots in the device memory.
Example:
If the device name has not been defined, no numbers have been set and the entered
command is
the response is:
If, after this, the command
is entered, the response is:
TEL <no1> <no2> <no3> <no4> <no5>
TEL <device name if specified>
1: <memory slot 1 telephone no>
.
.
5: <memory slot 5 telephone no>
TEL. +35840111111 +35840222222 +35840333333
TEL
1: +35840111111
2: +35840222222
3: +35840333333
TEL +35840444444
TEL
1: +35840111111
2: +35840222222
3: +35840333333
4: +35840444444
Telephone number setting command
End user telephone numbers in international
format delineated with spaces.