SAT3 Specifications
Signaling DTMF (50 msec tone bursts)
Loop Current 25 ma minimum
Relay Output: Dry contact relay 2A 48V maximum.
Normally open relay. Form C.
Number of relays: 2
System Connections:
Individual phone lines or PBX analog extensions recommended.
Temp. –20ºF to +140ºF (6ºC to 60ºC);
Relative humidity: 5% - 95% non-condensing.
Faceplate: Stainless steel
Weather resistant call button, microphone and speaker openings reduce damage
from vandalism.
Water resistant 3½" speaker, water resistant microphone.
Technical tools required for basic troubleshooting and repair:
Lineman's Test Set (Butt set)
Digital Multimeter (capable of DC current measurements)
3/32" Slotted Screwdriver
#15 Tamper-Torx
Security Bit