9.4.3 "Fault indicating relay" + "Pacing relay" output (identity code 4 + 5)

2
P_SI_0010_SW
Fig. 15: Pump assignment
Identity code 4 + 5
P_SI_0044
Fig. 16: Cable assignment
A fault indicating / pacing relay can optionally be ordered. The pacing
output is electrically-isolated by means of an optocoupler with a semicon‐
ductor switch. The second switch is a relay.
The fault indicating /pacing relay can be retrofitted and is operational once
attached to the relay board - refer to the "Operating Instructions for Retro‐
fitting Relays for Beta b".
Electrical interface
for fault indicating relays:
Data
3
Maximum contact load at 24 V and 50/60
1
Hz:
4
Minimum mechanical lifespan:
for semiconductor switch pacing relay:
Data
Residual voltage max. at I
Maximum current
Maximum voltage
Pacing pulse duration, approx.
Pin assignment
To pin
1
4
3
2
= 1 mA
c
VDE cable
Contact
yellow
NO (normally open)
green
C (common)
white
NO (normally open)
brown
C (common)
Electrical installation
Value Unit
8 A
200,000 switching
operations
Value Unit
0.4 V
100 mA
24 VDC
100 ms
Relay
Fault indi‐
cating relay
Fault indi‐
cating relay
Pacing relay
Pacing relay