Operation; Manual; Capacity; Functions - ProMinent Beta b BT4b Series Operating Instructions Manual

Solenoid metering pump
Hide thumbs Also See for Beta b BT4b Series:
Table of Contents

Advertisement

11

Operation

11.1

Manual

11.1.1

Capacity

11.1.2

Functions

WARNING!
Fire hazard with flammable media
Only with flammable media: They can be ignited by
oxygen.
The pump may not work if there is a mixture of feed
chemical with oxygen in the liquid end. A specialist
may need to take appropriate actions (using inert
gas, ...).
WARNING!
Danger of electric shock
Incompletely installed electrical options can allow mois‐
ture into the inside of the housing.
Knock-out openings in the pump housing must be
equipped with matching modules or be sealed in a
leak-tight manner.
WARNING!
Danger of electric shock
A mains voltage may exist inside the pump housing.
If the pump housing has been damaged, you must
disconnect it from the mains immediately. It may
only be returned to service after an authorised
repair.
Personnel:
n
The capacity is determined by the stroke length and the stroke rate.
The stroke length is adjusted by the stroke length adjustment knob within
a range of 0 ... 100 %. A stroke length of between 30 ... 100 % (SEK type:
50 ... 100 %) is recommended to achieve the specified reproducibility!
Data
Recommended stroke length, standard
type
Recommended stroke length, SEK type
The stroke rate can be set within a range of 10 ... 100 % using the multi‐
functional switch.
The pump has the following functions:
Instructed personnel
30 ... 100 %
50 ... 100 %
Operation
Value Unit
37