11
Operation
11.1
Manual
11.1.1
Capacity
11.1.2
Functions
WARNING!
Fire hazard with flammable media
Only with flammable media: They can be ignited by
oxygen.
–
The pump may not work if there is a mixture of feed
chemical with oxygen in the liquid end. A specialist
may need to take appropriate actions (using inert
gas, ...).
WARNING!
Danger of electric shock
Incompletely installed electrical options can allow mois‐
ture into the inside of the housing.
–
Knock-out openings in the pump housing must be
equipped with matching modules or be sealed in a
leak-tight manner.
WARNING!
Danger of electric shock
A mains voltage may exist inside the pump housing.
–
If the pump housing has been damaged, you must
disconnect it from the mains immediately. It may
only be returned to service after an authorised
repair.
Personnel:
n
The capacity is determined by the stroke length and the stroke rate.
The stroke length is adjusted by the stroke length adjustment knob within
a range of 0 ... 100 %. A stroke length of between 30 ... 100 % (SEK type:
50 ... 100 %) is recommended to achieve the specified reproducibility!
Data
Recommended stroke length, standard
type
Recommended stroke length, SEK type
The stroke rate can be set within a range of 10 ... 100 % using the multi‐
functional switch.
The pump has the following functions:
Instructed personnel
30 ... 100 %
50 ... 100 %
Operation
Value Unit
37