Start up

10
Start up
34
WARNING!
Dangerous reactions are possible due to contact of feed
chemical with water
The feed chemical can mix and react in the liquid end
with water remaining after testing in the factory.
Read the safety data sheet on the feed chemical.
Blast the liquid end with compressed air.
Flush the liquid end with a suitable medium through
the suction connector.
WARNING!
Fire hazard with flammable media
Only with flammable media: They can be ignited by
oxygen.
The pump may not work if there is a mixture of feed
chemical with oxygen in the liquid end. A specialist
may need to take appropriate actions (using inert
gas, ...).
CAUTION!
Danger with hazardous feed chemicals
Contact with the feed chemical is possible provided the
following handling instructions are adhered to.
If the feed chemical is dangerous, take appropriate
safety precautions when carrying out the following
handling instructions.
Adhere to the feed chemical safety data sheet.
CAUTION!
Warning of feed chemical spraying around
An unsuitable feed chemical can damage the parts of
the pump that come into contact with the chemical.
Take into account the resistance of the materials
that will come into contact with the medium when
selecting the feed chemical - refer to the ProMinent
Resistance List in the Product Catalogue or at
www.prominent.com.
CAUTION!
FDA pumps only: problems with hygiene possible
The O-rings supplied can become slightly contaminated
through packaging and shipment.
Flush through before using the pumps.
®