Diagrams For Setting The Capacity - ProMinent Beta b BT4b Series Operating Instructions Manual

Solenoid metering pump
Hide thumbs Also See for Beta b BT4b Series:
Table of Contents

Advertisement

18

Diagrams for setting the capacity

A
C [l/h]
0.9
0.8
180 min
-1
162 min
-1
0.7
144 min
-1
126 min
-1
0.6
108 min
-1
0.5
0.4
0.3
0.2
0.1
0
0
10
20
30
B
k
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0
1
2
4
5
A
C [l/h]
0.9
0.8
180 min
-1
162 min
-1
0.7
144 min
-1
126 min
-1
0.6
108 min
-1
0.5
0.4
0.3
0.2
0.1
0
0
10
20
30
B
k
1.4
1.2
1
0.8
0.6
0.4
0.2
0
1
2
3.5
Fig. 26: A) Capacity C at medium back pressure depending on the stroke length s for different stroke rates f. B) Associ‐
ated correction factors k depending on the back pressure p.
BT4b 1000
90 min
-1
72 min
-1
54 min
-1
36 min
-1
18 min
-1
40
50
60
70
80
90
s [%]
6
8
10
p [bar]
BT4b 0700
90 min
-1
72 min
-1
54 min
-1
36 min
-1
18 min
-1
40
50
60
70
80
90
s [%]
4
6
7
p [bar]
Diagrams for setting the capacity
A
C [l/h]
f [%]
0.9
100
0.8
180 min
-1
90
162 min
-1
0.7
144 min
-1
80
126 min
-1
0.6
108 min
-1
70
0.5
60
50
0.4
40
0.3
30
0.2
20
0.1
10
0
0
10
20
30
100
B
k
1.5
1
0.5
0
1
2
A
f [%]
C [l/h]
1.6
100
90
1.4
180 min
-1
162 min
-1
80
144 min
1.2
-1
126 min
-1
70
108 min
-1
1
60
0.8
50
40
0.6
30
0.4
20
0.2
10
0
100
0
10
20
30
B
k
1.5
1
0.5
0
1
2
4
BT4b 0400
90 min
-1
72 min
-1
54 min
-1
36 min
-1
18 min
-1
40
50
60
70
80
90
s [%]
3
4
p [bar]
BT4b 1601
90 min
-1
72 min
-1
54 min
-1
36 min
-1
18 min
-1
40
50
60
70
80
90
s [%]
6
8
11
13
16
p [bar]
f [%]
100
90
80
70
60
50
40
30
20
10
100
f [%]
100
90
80
70
60
50
40
30
20
10
100
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents