Enable Automatic Send TRAP – enable
automatic send TRAP by SNMP (above
TRAP Enable must be enable)
only v. 3.13
Time Interval (max value 10555) – period
to send TRAP from given INPUT,
accuracy 10 s
Time is set individually or with an NTP
server. When set manually each time you
reboot the machine need to set the time.
Output status when you turn on
or reboot the LAN Controller
Assigning an item number
for the currently connected
sensor DS18B20.
1. Connect chosen sensor (others should be removed), 2. Refresh the button „Read ID", (if it does
not appear ID, reset Lan Controller), 3. Enter the position number and press „Save to" button.
The read ID number will be assigned to the desired position, where „1" corresponds to INP6,
„2" is INP7 ... and „6" is INP11.
To add additional sensors, proceed as described above CONNECTED WITH ONLY ONE,
CURRENTLY added SENSOR.
If you want to remove the assignment, refresh the „Read ID" without sensor (so that the field
was empt) and memorize the redundant item number („Save to").
manual LAN Controller V2.0 – Firmware: HOME v. 3.13 and ISP v. 2.09 – LANKONT-002
only v. 3.13
only v. 2.09
www.tinycontrol.eu
19