Troubleshooting Flow - Mitsubishi Electric FDF71VNXVD Technical Manual

Hyper/micro inverter packaged air conditioners floor standing type
Hide thumbs Also See for FDF71VNXVD:
Table of Contents

Advertisement

11.2 Troubleshooting flow

(1)
List of troubles
Remote controller display
None
Operates but does not cool.
None
Operates but does not heat.
None
Earth leakage breaker activated
None
Excessive noise/vibration (1/3)
None
Excessive noise/vibration (2/3)
None
Excessive noise/vibration (3/3)
None
Power supply system error (Power supply to indoor control PCB)
None
Power supply system error (Power supply to remote controller)
INSPECT I/U
INSPECT I/U (When 1 or 2 remote controllers are connected)
INSPECT I/U
INSPECT I/U (Connection of 3 units or more remote controllers)
Communication error at initial operation
WAIT
None
No display
E1
Remote controller communication circuit error
E5
Communication error during operation
E6
Indoor heat exchanger temperature thermistor anomaly
E7
Return air temperature thermistor anomaly
E8
Heating overload operation
E10
Excessive number of connected indoor units (more than 17 units) by controlling with one remote controller
E11
Address setting error between master and slave indoor units
E14
Communication error of indoor units
E16
Indoor fan motor anomaly
E19
Indoor unit operation check
E20
Indoor fan motor rotation speed anomaly
E28
Remote controller temperature thermistor anomaly
E35
Cooling overload operation
E36
Discharge pipe temperature error
E37
Outdoor heat exchanger temperature thermistor anomaly
E38
Outdoor air temperature thermistor anomaly
E39
Discharge pipe temperature thermistor anomaly
E40
High pressure error (63H1 activated)
E41
Power transistor overheat
E42
Current cut
E45
Communication error between inverter PCB and outdoor control PCB
E47
Inverter PCB A/F module anomaly (Model FDC 71 only)
E48
Outdoor fan motor anomaly
E49
Low pressure error or low pressure sensor anomaly
E51
Inverter and fan motor anomaly
E53
Suction pipe temperature thermistor anomaly
E54
Low pressure sensor anomaly
E55
Underneath temperature thermistor anomaly (Models FDC 200, 250 only)
E57
Insufficient refrigerant amount or detection of service valve closure
E59
Compressor startup failure
E60
Compressor rotor lock error (Models FDC 200, 250 only)
Description of trouble
148
-
-
'11 • PAC-T-160
Reference page
149
150
151
152
153
154
155
156
157
158
159 〜 161
162
163
164
165
166
167
168
168-1
169
170
171
172
173
174
175
176
177
178
179
180, 181
182, 183
184
185
186
187, 188
189
190
191
192
193
194, 195
196
#

Advertisement

Table of Contents
loading

Table of Contents