Outdoor Units - Mitsubishi Electric FDF71VNXVD Technical Manual

Hyper/micro inverter packaged air conditioners floor standing type
Hide thumbs Also See for FDF71VNXVD:
Table of Contents

Advertisement

POWER SOURCE 1〜220ー240V 50Hz/1〜220V 60Hz
TB
F ( 20A)
RD
L1
WH
N
MCCB
YE/GN
T2
T1
F6 ( 5A)
T8
T9
T4
ELCB
RD
T5
N/F PWB3
T10
WH
T6
CNO2 ( WH)
F3 ( 4A)
T11
T13
3
1
T21
T22
CN01
CNW
CNG2
BK
CNG1
(WH)
(WH)
YE
(BK)
(BK)
T24
INV
PWB1
L1
CNI2
BL
CNI1
PWB2
(WH)
(WH)
T25
IPM
CNI4
BL
CNI3
(WH)
(WH)
T28 T29
T30
T26
T27
U
V
W
RD
CNA1
BL
(WH)
+
V W
C1
RD
U
CNA2
MS
BL
CNN
(WH)
CM
(YE)
3〜
DH
OPTIONAL
Power cable, indoor-outdoor connecting wires
MAX over current
Power cable size
Model
(A)
(mm )
2
71
17
3.5
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
Refer to installation manual or technical manual about usage of local setting switch.
Don't operate SW3-3,SW5-1,SW5-2,SW7,SW8
TB
OR
1
GY
TO INDOOR UNIT
2
POWER WIRES
1 2
SIGNAL WIRE
3
3
SM2
SM1
FM01
M
M
1 3
6 5 4 3 2 1
6 5 4 3 2 1
7
6
CNW2
CNEEV2
CNEEV1
CNFAN
(WH)
(OR)
(RD)
(WH)
52X1
52X3
52X4
LED1
LED2
CNIP
CNPS
CNR
CNS
CNH
CNTH
(WH)
(RD)
(PK)
(WH)
(YE)
(WH)
8
7
6
5
4
3
2
1
LPT
CH
20S
63H1
Tho-R1
Tho-D
Tho-S
Tho-A
Tho-IPM
Power cable length
indoor-outdoor
Earth wire size
(m)
wire size x number
(mm )
2
(mm )
2
21
Ø1.6mm x 3
Ø1.6mm
M
5
4
1
ON
ON
BK
CNQ1
(WH)
1 2 3 4
1 2 3
6
SW9
SW5
SW8
CNQ1
Mark
(WH)
BK
BL
ON
ON
BK
CNQ2
(BK)
1 2 3 4
1 2 3
BR
6
SW3
SW7
CNQ2
(BK)
OR
CNB
(RD)
RD
WH
YE
YE/GN
Tho-R2
GY
PK
Local setting switch SW3, SW5 ( Set up at shipment OFF)
SW3-1 Defrost control change The defrosting operation interval becomes
shorter by turning ON this switch.
This switch should be turned ON in the area
where outside temperature becomes below
the freezing point.
SW3-2 Snow guard fan
When this switch is turned ON, the outdoor
unit fan will run for 10 seconds in every 10
control
minutes, when outdoor temperature falls to
3°C or lower and the compressor is not
running when the unit is used in a very
snowy country, set this switch to ON.
SW5-3,4 Trial operation
Method of trial operation
1. Trial operation can be performed by using
SW5-3.
2. Cooling trial operation will be performed
when SW5-4 is OFF, and heating trial
operation when SW5-4 is ON.
3. Be sure to turn OFF SW5-3 after the trial
operation is finished.
ITEM
DESCRIPTION
CM
Compressor motor
FM01
Fan motor
CH
Crankcase heater
DH
Drain pan heater
Auxilliary relay ( for CH)
52X1
Auxilliary relay ( for 20S)
52X3
Auxilliary relay ( for DH)
52X4
20S
Solenoid valve for 4 way valve
SM1
Expansion valve for cooling
SM2
Expansion valve for heating
High pressure switch
63H1
Tho-A
Thermistor
(Outdoor air temp.)
Tho-D
Thermistor
(Discharge pipe temp.)
Color
Tho-R1,R2
Thermistor
(Heat exchanger temp.)
Black
Blue
Tho-S
Thermistor
(Suction pipe temp.)
Brown
Thermistor (IPM)
Orange
Tho-IPM
Low pressure sensor
Red
LPT
Intelligent power module
White
IPM
Yellow
TB
Terminal block
Yellow/Green
F,F3
Fuse
Gray
CnA〜Z
Connector
Pink
SW9
Pump down switch
SW3,5
Local setting switch
Indication lamp ( GREEN)
LED1
Indication lamp ( RED)
LED2
L1
Reactor

Advertisement

Table of Contents
loading

Table of Contents