P0851 – ETHERCAT ACCESSORY STATUS
Range:
Properties:
Description:
Indicates the status of EtherCAT Interface, related to the data exchange between network master and CFW11
frequency inverter.
Value
0 = Inactive
1 = Access error
2 = Watchdog error
3 = Offline
4 = Online
P0852 – ETHERCAT LINK STATUS
Range:
Properties:
Description:
Parameter that provides information about the state of communication for each available Ethernet port on the module.
Uses a binary field, where each bit represents a different information:
Bit
15
14
Function
0 = Inactive
1 = Access error
2 = Watchdog error
3 = Offline
4 = Online
ro, ecat
Table 5.5: Indications of parameter P0851
Interface not installed or not recognized by the device.
Error during the initialization procedure of EtherCAT module.
Error in the watchdog mechanism between accessory and device, responsible by
checking if data update between both are running successfully.
EtherCAT module running properly, but there is no cyclic data exchange with the network
master.
EtherCAT module running properly, with cyclic data exchange with the network master.
0000h ... FFFFh
ro, ecat
13
12
11
10
Description
9
8
7
6
Parameterization
Default: -
Default: -
5
4
3
2
CFW11 | 18
1
0