Parker Hannifin S.p.A Divisione S.B.C.
b181.9
Enable counter position from CAM1 to global counter(Pr130:131). This
command, b181.9=1, enable the reference of CAM1. This value is added
algebraically to global counter of reference.
b181.10 Enable counter position from CAM 2 to global counter(Pr130:131). This
command, b181.9=1, enable the reference of positioner. This value is added
algebraically to global counter of reference.
b181.11 Enable counter position from trapezoidal positioner to global counter
(Pr130:131). This command, b181.9=1, enable the reference of CAM2. This value
is added algebraically to global counter of reference.
b181.13 Enable counter position from CAM 1 to reference position (Pr60:61).
b181.14 Enable counter position from CAM 2 to reference position (Pr60:61).
b181.15 Enable counter position from trapezoidal positioner to reference position
(Pr60:61).