Parker Hannifin S.p.A. Divisione S.B.C.
10.3.2.5
Object 605A
The parameter quick stop option code determines what action should be taken if the Quick
Stop Function is executed.
OBJECT DESCRIPTION ENTRY DESCRIPTION
DATA DESCRIPTION
Value Description
0
1
2
5
6
10.3.2.6
Object 605E
The parameter Fault reaction option code determines what action should be taken if a fault
occurs.
OBJECT DESCRIPTION
ENTRY DESCRIPTION
152
: Quick stop option code
h
INDEX
605Ah
Name
Quick stop option code
Object Code VAR
Data Type
INTEGER16
Category
Optional
Access
PDO Mapping No
Value Range
Default Value
disable drive function
slow down on slow down ramp
slow down on quick stop ramp
slow down on slow down ramp and stay in QUICK STOP
slow down on quick stop ramp and stay in QUICK STOP
: Fault reaction option code
h
INDEX
605E
Name
Fault reaction option code
Object Code VAR
Data Type
INTEGER16
Category
Optional
Access
PDO Mapping No
Value Range
Default Value
user's manual TWIN-N and SPD-N
rw
INTEGER16
2
h
rw
INTEGER16
2