6.2 Binary parameters

Par.
b39.0
Undervoltage in continuous current. b39.0=1 When the drive is
supplied in continuous voltage, this bit permits the control of the
undervoltage alarm.
b39.1
(1) Abilitato Pr207 - Valore soglia di sovratensione e di
frenatura impostati a partire da Pr207. Se viene abilitato questo
bit, occorre impostare il valore di soglia della massima tensione nel
parametro Pr207.
b39.2
(1) if feedback supply is active.
b39.3
Power supply <150Vac.
b39.4
Mains not 3 phase. When the mains is not 3 phase, the bit is equal
to 1.
b39.9
(1) Encoder zero point dog fine tuning.
b39.13 CANopen: send user fault. User alarm message.
b39.14 CANopen Node Guard watchdog. (see par. " CANopen ").
b39.15 Watchdog dell'encoder CAN.
b40.0
Selection of the first or second full scale of the speed reference:
If = 0, Pr2 will be used to rate the analogue reference. If = 1,
parameter Pr3 will be used.
b40.1
Activation of the algorithm to suppress vibration at 0 speed: If
= 1, the algorithm is turned on.
b40.2
Selection of the reserved/user reference: If = 1, the reserved
reference of the operating mode in use is used. If = 0, the reference
selected by b40.0, b40.12 and b40.13 is used.
b40.3
Reference hold: If = 1, the reference will not be updated and the
motor will not follow the variations of the input reference. If = 0,
the reference will follow the variation of the input reference.
b40.4
Left limit switch: If = 1 and the reference selected requires
negative speed, the reference is set to 0 following the ramp set in
Pr12. If = 0, no control is made.
b40.5
Right limit switch: Default=0. If = 1 and the reference selected
requires negative speed, the reference is set to 0 following the ramp
set in Pr12. If = 0, no control is made.
b40.6
Stop function: If = 1, the motor is set to zero speed following the
ramp set in Pr12.
b40.7
Selection of the absolute/relative speed window: If = 0, the speed
window Pr14 Pr15 b41.1 will function in relative mode. Otherwise,
if = 1, it will function in absolute mode.
b40.8
Analogue torque limit: Default=0. If = 1, Pr22 will be used and
also the auxiliary analogue input in order to limit the torque to the
motor. The sign of voltage at aux. differential analog input doesn't
interest.
b40.9
Software enable: . If = 0, the converter cannot be enabled.
b40.10 Low voltage. Activates low voltage management (from 40 to
180V~, and from 57Vdc to 255Vdc), so the maximum speed of the
axis is lower.
65
Description
user's manual TWIN-N and SPD-N
Def.
Field
0
R/W
M
0
0
R/W
M
0
R/W
M
0
R/W
M
0
R/W
M
0
R/W
M
0
R/W
M
0
R/W
M
0
R/W
M
0
R/W
M
1
R/WM
0
W