Timer Off
Command
Resets the timer counter TC(k) to 0 and starts
the timer in free-run mode.
Timing chart
(1)
DriveProgramming User's Manual (I622-E1)
Description
Flowchart method
timer off TD(k)
↓
(2)(3)
(4)
(5)(6)
(7)
6 DriveProgramming Commands
TD(k): the timer output contact of the timer that
you use (range of k is 0 to 7)
Format
Text language method
timer off TD(k)
(1) The timer is in a free-run state.
(2) The "timer set" command is started.
(3) The delay operation is in progress.
(4) The time elapsed.
(5) The "timer set" command is started.
(6) The delay operation is in progress.
(7) The time elapsed.
(8) The "timer off" command is started.
(8)(9)
(9) The timer is in a free-run state.
Argument
6 - 51
6