Omron RX2 Series User Manual page 105

Driveprogramming, cx-drive
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

Parameter Control Commands
Command
Argument 1
ChgParam
<parameter>
MonParam
<variable>
Inverter Control Commands
Command
Argument 1
: =
FW
: =
RV
stop
trip
<variable/
constant>
: =
SET-Freq
: =
ACCEL
DECEL
: =
DriveProgramming User's Manual (I622-E1)
Argument 2
Argument 3
: =
<variable/
constant>
: =
<parameter>
Argument 2
Argument 3
1
1
<variable/
constant>
<variable/
constant>
<variable/
constant>
6 DriveProgramming Commands
Argument 4
Argument 5
Argument 4
Argument 5
Description
Replaces the content
of <parameter> with
<variable/constant>.
Assigns the content of
<parameter> to
<variable>.
Description
Operates the inverter
in the forward direction.
Operates the inverter
in the reverse direction.
Decelerates the
inverter to a stop.
Note: This command
acts as a reset when the
inverter is in a trip state.
Issues a user trip
according to <variable/
constant>.
Assigns <variable/con-
stant> (× 0.01 Hz) to
the inverter frequency
reference variable.
Assigns <variable/con-
stant> (× 10 ms) to the
inverter acceleration
time variable.
Assigns <variable/con-
stant> (× 10 ms) to the
inverter deceleration
time variable.
6 - 9
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g3rx2 series

Table of Contents