WebRelay-10 Users Manual
Appendix H: Specifications
Power Requirements
Input Voltage: 9-28 VDC
Current:
10 Mbps Network Speed
Power Supply
9 VDC
12 VDC
24 VDC
100 Mbps Network Speed
Power Supply
9 VDC
12 VDC
24 VDC
I/O
- 10 Relays
- 2 Inputs (WebRelay-10 Plus™ only)
- Up to 8 Temperature and/or Humidity Sensors (WebRelay-10 Plus™ only)
Relay Contacts
Load Type:
Contact Form:
Contact Material:
Max Voltage:
Recommended Max Current:
Absolute Max Current:
Contact Resistance:
Electrical Life:
Mechanical Life:
Relay Compliance:
Relay and Power Input Connections
Tab Terminals:
Wire
Environmental
Operating Temperature:
Storage Temperature:
Humidity:
Altitude:
Environmental Rating:
Installation:
Xytronix Research & Design, Inc.
See table below for typical values at 25°C.
No Relays Energized
114 mA
86 mA
46 mA
No Relays Energized
200 mA
151 mA
80 mA
General purpose
SPDT (form C)
Silver Nickel
277 VAC (general purpose); 30 VDC (NC contact, resistive)
15A
40A
<30 milliohms initial
100K cycles, typical @ full-rated load (higher w/ smaller load)
10M cycles, typical
UL/CUL listed relays (E197852)
1/4" x .032"
Use UL listed quick-connect connectors suitable for field connections.
Use crimping tool as specified by the connector manufacturer.
Use wire rated for 75ºC (min) for connections to the relays.
-40ºC to 65.5ºC (-40ºF to 150ºF)
-40ºC to 85ºC (-40ºF to 185ºF)
5% to 95% non condensing
Up to 2,000 meters
Pollution Degree 2
Must be installed inside an NRTL certified industrial control panel
or similar NRTL certified fire/electrical enclosure.
5 Relays Energized
692 mA
516 mA
264 mA
5 Relays Energized
779 mA
580 mA
295 mA
Appendix H: Specifications
10 Relays Energized
1320 mA
959 mA
477 mA
10 Relays Energized
1391 mA
1036 mA
511 mA
page 101
Need help?
Do you have a question about the WebRelay-10 X-WR-10R12-I and is the answer not in the manual?