Error Messages On The Smart-Control - REMKO WKF-compact Series Assembly And Operating Instructions Manual

Inverter heat pumps
Hide thumbs Also See for WKF-compact Series:
Table of Contents

Advertisement

14.3

Error messages on the Smart-Control

Operating messages, warnings and error display on the Smart-Control
Operating messages
ID
Description
Storage tank 1: Max.
ID6000
temperature reached
ID6001 HW request
Heat pump compressor
ID6002
start
Switching cycle disa-
ID6003
bled (I/O2)
ID6005 Internal pump lead time
Switching cycle disa-
ID6006
bled
ID6007 Min. holding time
ID6008 Disable signal
ID6009 Disable signal (I/O 2)
Heat pump compressor
ID6010
start (I/O 2)
ID6012 Defrosting HP (I/O 2)
Pump internal
ID6020
after-run time
ID6103 Heat demand HP
ID6104 Cooling demand HP
ID6105 Defrost heat pump
ID6107 Standby mode enabled
Random delay after
ID6108
power failure
Outdoor temp. Heat
ID6109
pump usable limit
Heat pump bivalence
ID6111
temperature
ID6113 Solar heating
Low pressure differ-
ID6115
ence
Maximum defrosting
ID6116
period
Desig.
Details
The temperature on one of the probes in storage tank 1 is
higher than the maximum permitted storage tank temperature
There is an active requirement to charge the storage tank
Heat pump compressor start
The heat pump was disabled in order to reduce the compres-
sor's switching cycles
The internal pump runs at reduced speed during the pump
lead time
The heat pump was disabled in order to reduce the compres-
sor's switching cycles
The heat pump is disabled due to a minimum holding time
S16
The heat pump is disabled due to a disable signal
The heat pump is disabled due to a disable signal
Heat pump compressor start
Defrost heat pump
The internal pump runs at a reduced speed during the pump
after-run time
Heat demand, heat pump
Cooling demand, heat pump
Defrost heat pump
Standby mode enabled
Random delay after power failure (up to 200 seconds after
power returns) - the purpose of the random delay is to avoid a
system overload due to many consumers being switched on
at the same time
Outdoor temp. Heat pump usable limit - the heat pump is disa-
bled due to the usable limits being exceeded or not being
reached
Heat pump bivalence temperature - the heat pump is disabled
because the temperature has dropped below the bivalence
temperature
Solar heating - heat generators are disabled
The pressure difference is too low to start the compressor
Maximum defrosting period
81