REMKO WKF / WKF-compact
ID
Description
ID7315 WKF fault code E461
ID7316 WKF fault code E467
ID7317 WKF fault code E462
ID7318 WKF fault code E463
ID7319 WKF fault code E554
ID7320 WKF fault code E556
Open contact -
ID7328
2nd mixed heating cycle
return flow temp.
Short circuit - 2. mixed
ID7329
heating cycle return
flow temp.
Negative temp. differ-
ID7333
ential
ID7334 Comm. signal
Warnings
ID
Description
Temperature discrep-
ID8102
ancy in solar cycle
ID8103 Overnight collector
temperature
ID8105 Target flow rate
ID8106 Low pressure
ID8107 Compressor status
ID8108 Compressor start error
ID8109 EVD EVO probe fault
ID8110 Driver offline
ID8111 Device offline
Anti-freeze protection
ID8132
active
HW storage tank set
ID8138
temp.
86
Desig.
Details
Implausibly low current at the current probe or fault on the
inverter board at compressor start (can occur with compressor
damage)
Missing phase conductor on the compressor
Overcurrent fault (primary side) - check power supply / fuse
for the EMI board
Compressor overtemperature (OLP). Probe value greater than
115°C (below 12.7 kohm). Can be caused by a jammed
expansion valve
Refrigerant quantity / refrigerant loss malfunction
Power ratings for the com. kit board (IM) and the motherboard
(AM) differ - check board versions.
S06
Open contact - 2. mixed heating cycle return flow temp.
S06
Short circuit - 2. mixed heating cycle return flow temp.
The temperature difference when the heat generator is active
is implausible
Communication between operating unit SMT 1 and power unit
SMT 1 I/O was interrupted.
Desig.
Details
The collector temperature is at least 60K higher than the
storage tank temperature
A collector temperature of at least 45°C (113 °F) occurred
overnight
The flow rate has dropped below the target flow rate
Low pressure. The compressor is disabled temporarily
The active operating mode is safety mode because the com-
pressor is active without demand
Compressor start error
EVD EVO probe fault
Driver offline
Device offline - please check the data connection between the
controller board and the inverter
The anti-freeze protection function is currently active - check
the room climate mode set
The hot water storage tank set temperature was reduced due
to low outside temperatures