Menu 8
8-2 Rot Cold Milk
2000 RPM
8-3 Rot Cold Foam
350 RPM
8-4 TBlock Stdby Temp
0060 °C
8-5 Milk Suction Time
02.0 sec
8-6 Time Before Milk
02.0 sec
8-7 Water After Milk
0.5 sec
8-8 Time After Milk
03.00 sec
8-9 Milk Tank Temp
0005 °C
Menu 9
9 Machine status
9- Date Time
On
9-2 Temp Sensors
© 2006 by Thermoplan, Subject to change
Technical Manual
In menu 8-2 you can adjust the pump rotation for milk for cold milk products.
In menu 8-3 you can adjust the pump rotation for milk for cold milk foam products.
In menu 8-4 you can set the standby temperature of the thermoblock with the Plus-/Minus levers. Range is between
20 and 70 °C.
In menu 8-5 you can adjust the time for the Suction of the milk.
During this time, the milk is sucked in. The milk-transportation simplifies to the Labyrintplatte.
In menu 8-16 can defined how long the thermoblock valve is open before the milk product runs out. The water that is
in tne milk system available, flow through a third way out, so that only the hot milk in the cup runs out.
In menu 8-7 you can set the water quantity after every milk product. This water quantity is importent, that we have
no milk in system after a milk product. The time, means how long the rins valve open.
In menu 8-18 you can defined how long the thermoblock valve is open before the milk product runs out. With this
time is prevented, that on the end of the milk product no water can flow in the cup.
In menu 8-9 you can set the desired temperature of the milk tank with the Plus-/Minus levers. Range is between 03
and 25 °C.
In this menu you can switch-on/off the additional display readouts.
By pressing the enter key you access the menu.
In menu 9- you can swith on/off the TIme and Date on the display.
In menu 9-2 you can switch on/off the Temperatur sensors on the display. If the sensors on, than shows the display;
Thermoblock temperature (SBT), Coffee boiler temperature (CBT), Milk temperature (MIT) and the Interior temperature
(COL).