Thermoplan Tiger Programming Manual page 19

Hide thumbs Also See for Tiger:
Table of Contents

Advertisement

Menu 8
8 Mach Parameters
8- Boiler Temp
092 °C
8-3 Over Temp
05 °C
8-4 Pump Rot Coffee
200 RPM
8-5 Pump Rot Tea
0700 RPM
8-6 Milk Pump Temp
0085 °C
8-7 Milk Temp
0095 °C
8-8 Foam Pump Temp
0085 °C
8-9 Foam Temp
0095 °C
8-0 Pump Rot Milk
0700 RPM
8- Pump Rot Foam
350 RPM
© 2006 by Thermoplan, Subject to change
Technical Manual
In this menu you can set the machine parameters.
By pressing the enter key you access the menu.
In menu 8- you can set the desired water temperature in the boiler with the Plus-/Minus levers. Range is between 60
and 05 °C.
In menu 8-3 you can set the overheat temperature of the boiler with the Plus-/Minus levers. 5 minutes after the last
dispensed coffee product this function heats up the boiler by the programmed value over the standard temperature to
prevent the loss of temperature. The range is between 0 and 5 °C.
In menu 8-4 you can adjust the speed of the pump rotation for coffee products.
In menu 8-5 you can adjust the speed of the pump rotation for the tea.
In menu 8-6 you can set the milk pump temperature on the thermoblock with the Plus-/Minus levers. This temperature
is the release for the milk pump. Range is between 20 and 40 °C.
In menu 8-7 you can set the milk temperature of the NTC on the thermoblock. Range is between 20 and 40 °C.
In menu 8-8 you can set the milk foam pump temperature on the thermoblock with the Plus-/Minus levers. This tem-
perature is the release for the milk pump. Range is between 20 and 40 °C.
In menu 8-9 you can set the milk foam temperature of the NTC on the thermoblock. Range is between 20 and 40
°C.
In menu 8-0 you can adjust the speed of the pump rotation for the milk.
In menu 8- you can adjust the speed of the pump rotation for milk foam products.
Tiger REV-8